Alimentatori programmabili AC/DC2018-11-12T17:44:00+00:00

Alimentatori programmabili AC/DC serie Bench XR 600W

Informazioni generali

• Serie di alimentatori programmabili ultracompatti (mezzo rack , 1 unità)
• Autorange
• Nuovo brevetto: Wireless Digital Remote Sense
• Protezioni OCP e OVP
• Interfacce standard incluse: LAN (LXI), USB e analogiche
• Display OLED
• Protezioni OCP e OVP
• Compatibilità comandi Keysight 603x, Sorenson DLM e Xantrex XFR

Model Power W Voltage V Current A Dimensions
Bench 30-33 XR  600  0 – 30  0 – 33  44 x 224 x 262 mm
Bench 50-20 XR  600  0 – 50  0 – 20   44 x 224 x 262 mm
Bench 100-10 XR  600  0 – 100  0 – 10  44 x 224 x 262 mm
Bench 200-5 XR  600  0 – 200  0 – 5  44 x 224 x 262 mm
Bench 400-2.5 XR  600  0 – 400  0 – 2,5   44 x 224 x 262 mm

Alimentatori programmabili AC/DC serie Rack XR 1500W

• Serie di alimentatori programmabili ultracompatti (mezzo rack , 1 unità)
• Autorange
• Nuovo brevetto: Wireless Digital Remote Sense
• Protezioni OCP e OVP
• Interfacce standard incluse: LAN (LXI), USB e analogiche
• Display OLED
• Protezioni OCP e OVP
• Compatibilità comandi Keysight 603x, Sorenson DLM e Xantrex XFR

Model Power W Voltage V Current A Dimensions
Rack 30-70 XR  1500  0 – 30  0 – 70   44 x 483 x 394 mm
Rack 50-40 XR  1500  0 – 50  0 – 40   44 x 483 x 394 mm
Rack 100-20 XR  1500  0 – 100  0 – 20   44 x 483 x 394 mm
Rack 200-10 XR  1500  0 – 200  0 – 10   44 x 483 x 394 mm
Rack 400-5 XR  1500  0 – 400  0 – 5   44 x 483 x 394 mm

 

 


Alimentatori programmabili AC/DC  serie LAB/SMP(E) 0,5 – 2,4 KW

Informazioni generaliDatasheet Alimentatori programmabili LAB/SMP

• Alimentatori programmabili ad alta efficienza (fino al 94%)
• Design compatto 15kW in 3 U
• Possibilità di utilizzo in parallelo fino a 6 unità
• Interfaccia intuitiva
• Modalità: ConstantCurrent ,ConstatVoltage, ConstantResistance e ConstantPower
• Memoria per curve V/I custom con SD card esterna (es. simulazione pannelli solari e sequenza di uscita)
• Modalità VI, VIP, VIR e simulazione pannelli solari
• Script per controllo sequenziale caricabile su memory card SD (funzionamento autonomo senza PC)
• Funzione data logging a intervalli regolabili con salvataggio su memory card SD
• Display grafico
• Interfaccia analogica galvanicamente isolata 5/10 VDC per impostare e leggere i valori in uscita
• Interfacce di comunicazione disponibili: IEEE 488, RS232/485, USB e LAN
• Script control: possibilità di programmare sequenze e registare i valori in uscita su scheda SD.  Questa caratteristica permette di creari stazioni di test stand alone senza la necessità di usare PC di controllo
• Limitazione uscita massima selezionabile attarverso le variabili Vmax e Imax
• Modelli custom su richiesta

Modelli

Model Power W Voltage V Current A Dimensions
LAB/SMP 115 1.200 0 – 15 0 – 80 19″ x 1 HE x 440 mm
 LAB/SMP 135  1.200  0 – 35  0 – 35  19″ x 1 HE x 440 mm
 LAB/SMP 145  1.200  0 – 45  0 – 30  19″ x 1 HE x 440 mm
 LAB/SMP 170  1.200  0 – 70  0 – 20  19″ x 1 HE x 440 mm
 LAB/SMP 1150  1.200  0 – 150  0 – 8  19″ x 1 HE x 440 mm
 LAB/SMP 1300  1.200  0 – 300  0 – 4  19″ x 1 HE x 440 mm
 LAB/SMP 1600  1.200  0 – 600  0 – 2  19″ x 1 HE x 440 mm
LAB/SMP 11200 1.200 0 – 1200 0 – 1 19″ x 1 HE x 440 mm
 LAB/SMP 215  2.400  0 – 15  0 – 160  19″ x 1 HE x 440 mm
 LAB/SMP 235  2.400  0 – 35  0 – 68  19″ x 1 HE x 440 mm
 LAB/SMP 245  2.400  0 – 45  0 – 53  19″ x 1 HE x 440 mm
 LAB/SMP 270  2.400  0 – 70  0 – 34  19″ x 1 HE x 440 mm
 LAB/SMP 2150  2.400  0 – 150  0 – 16  19″ x 1 HE x 440 mm
 LAB/SMP 2300  2.400  0 – 300  0 – 8  19″ x 1 HE x 440 mm
 LAB/SMP 2600  2.400  0 – 600  0 – 4  19″ x 1 HE x 440 mm
 LAB/SMP 21200  2.400  0 – 1200  0 – 2  19″ x 1 HE x 440 mm

Options

Suffix Description
../3P400 i/p 3 x 400 / 360 – 440 VAC
../ATE Ohne manuelle Bedienung
../ATI5/10 Isolated analogue interface 0-5/0-10VDC set and monitor
../LT Interface IEEE 488
../LTRS485 Interface RS485
../LTRS232 Interface RS232
../LAN Interface LAN
../USB Interface USB
../KFZ12 car starting curve 12VDC
../KFZ24 car starting curve 24VDC
../OPT Output characteristics
../SD SD card slot
../M-S Master-Slave Option for max. 20 kW power

Caratteristiche tecniche

Input Voltage Specification
Volltage Range 2 kW 230 VAC +/-10% /PFC | 1,2 kW 90 – 264 VAC / PFC
Frequency 47 – 63 Hz
EMC ans Safety Standards
IT Equipment – Safety EN 60950
Emission standard
for industrial environments EN 61000-6-4
Immunity
for industrial environments EN 61000-6-2
Programming & Controls
Static Voltage Regulation +/- 0,05% + 2mV
Static Current Regulation +/- 0,1% + 2mA
Dynamic Load Regulation < 2ms (typ.)
Rippel < 0,2% (typ.)
Stability +/-0,05%
Programming Accuracy (Vout) +/- 0,05% +2mV
Isolation 3000 V
Over Voltage Protection 0 – 120% Vmax
Cuircuit Protection OC/OV/OT/OP
Line Regulation < +/- 0,1% + 2mV
Static Load Regulation < +/- 0,1% + 2mV
Output Specifications
Output Control & Monitoring Front panel and/or optional Analog 0 to +5V/+10V Standard & isolated /
Digital 12 bit: RS232, RS485, IEE-488, LAN, USB, SD card
Enviromental
Operation Temperature Range 0 – 50°C
Humidity 0 – 90% (non-condensing)
Power Reduction 50 – 70°C – 2%/°C
Storage Humidity 0 – 95% (non-condensing)
Storage Temperature Range -45°C – 85°C
Vibration 10 – 55Hz / 1min / 2G XYZ
Shock < 20G

Alimentatori programmabili AC/DC serie LAB/SMS 3 – 10 KW

Informazioni generaliDatasheet alimentatore LAB/SMS LAB/HP

• Alimentatori programmabili ad alta efficienza (fino al 94%)
• Design compatto fino 1okW in 2 U
• Possibilità di utilizzo in parallelo fino a 6 unità
• Interfaccia intuitiva
• Modalità: ConstantCurrent ,ConstatVoltage, ConstantResistance e ConstantPower
• Memoria per curve V/I custom con SD card esterna (es. simulazione pannelli solari e sequenza di uscita)
• Modalità VI, VIP, VIR e simulazione pannelli solari
• Script per controllo sequenziale caricabile su memory card SD (funzionamento autonomo senza PC)
• Funzione data logging a intervalli regolabili con salvataggio su memory card SD
• Display grafico
• Interfaccia analogica galvanicamente isolata 5/10 VDC per impostare e leggere i valori in uscita
• Interfacce di comunicazione disponibili: IEEE 488, RS232/485, USB e LAN
• Script control: possibilità di programmare sequenze e registare i valori in uscita su scheda SD.  Questa caratteristica permette di creari stazioni di test stand alone senza la necessità di usare PC di controllo
• Limitazione uscita massima selezionabile attarverso le variabili Vmax e Imax
• Modelli custom su richiesta

 

Modelli

Type

Power W

Voltage V

Current A

Dimensions

LAB/SMS 315 3.000 0 – 15 0 – 200 19“ x 2HE x 440mm
LAB/SMS 335 3.000 0 – 35 0 – 90 19“ x 2HE x 440mm
LAB/SMS 345 3.000 0 – 45 0 – 70 19“ x 2HE x 440mm
LAB/SMS 370 3.000 0 – 70 0 – 45 19“ x 2HE x 440mm
LAB/SMS 3150 3.000 0 – 150 0 – 20 19“ x 2HE x 440mm
LAB/SMS 3300 3.000 0 – 300 0 – 10 19“ x 2HE x 440mm
LAB/SMS 3600 3.000 0 – 600 0 – 5 19“ x 2HE x 440mm
LAB/SMS 31000 3.000 0 – 1000 0 – 3 19“ x 2HE x 440mm
LAB/SMS 31200 3.000 0 – 1200 0 – 2,6 19“ x 2HE x 440mm
LAB/SMS 420 4.000 0 – 20 0 – 200 19“ x 2HE x 440mm
LAB/SMS 435 4.000 0 – 35 0 – 115 19“ x 2HE x 440mm
LAB/SMS 445 4.000 0 – 45 0 – 90 19“ x 2HE x 440mm
LAB/SMS 470 4.000 0 – 70 0 – 60 19“ x 2HE x 440mm
LAB/SMS 4150 4.000 0 – 150 0 – 30 19“ x 2HE x 440mm
LAB/SMS 4300 4.000 0 – 300 0 – 15 19“ x 2HE x 440mm
LAB/SMS 4600 4.000 0 – 600 0 – 7 19“ x 2HE x 440mm
LAB/SMS 41000 4.000 0 – 1000 0 – 4 19“ x 2HE x 440mm
LAB/SMS 525 5.000 0 – 25 0 – 200 19“ x 2HE x 440mm
LAB/SMS 535 5.000 0 – 35 0 – 150 19“ x 2HE x 440mm
LAB/SMS 545 5.000 0 – 45 0 – 120 19“ x 2HE x 440mm
LAB/SMS 570 5.000 0 – 70 0 – 75 19“ x 2HE x 440mm
LAB/SMS 5150 5.000 0 – 150 0 – 35 19“ x 2HE x 440mm
LAB/SMS 5300 5.000 0 – 300 0 – 17 19“ x 2HE x 440mm
LAB/SMS 5600 5.000 0 – 600 0 – 8,5 19“ x 2HE x 440mm
LAB/SMS 51000 5.000 0 – 1000 0 – 5 19“ x 2HE x 440mm
LAB/SMS 51200 5.000 0 – 1200 0 – 4,2 19“ x 2HE x 440mm
LAB/SMS 615 6.000 0 – 15 0 – 400 19“ x 2HE x 600mm
LAB/SMS 620 6.000 0 – 20 0 – 300 19“ x 2HE x 600mm
LAB/SMS 635 6.000 0 – 35 0 – 175 19“ x 2HE x 600mm
LAB/SMS 645 6.000 0 – 45 0 – 140 19“ x 2HE x 600mm
LAB/SMS 670 6.000 0 – 70 0 – 90 19“ x 2HE x 600mm
LAB/SMS 6150 6.000 0 – 150 0 – 40 19“ x 2HE x 600mm
LAB/SMS 6300 6.000 0 – 300 0 – 20 19“ x 2HE x 600mm
LAB/SMS 6600 6.000 0 – 600 0 – 10 19“ x 2HE x 600mm
LAB/SMS 61000 6.000 0 – 1000 0 – 6 19“ x 2HE x 600mm
LAB/SMS 61200 6.000 0 – 1200 0 – 5 19“ x 2HE x 600mm
LAB/SMS 820 8.000 0 – 20 0 – 440 19“ x 2HE x 600mm
LAB/SMS 825 8.000 0 – 25 0 – 320 19“ x 2HE x 600mm
LAB/SMS 835 8.000 0 – 35 0 – 230 19“ x 2HE x 600mm
LAB/SMS 845 8.000 0 – 45 0 – 180 19“ x 2HE x 600mm
LAB/SMS 870 8.000 0 – 70 0 – 115 19“ x 2HE x 600mm
LAB/SMS 8150 8.000 0 – 150 0 – 55 19“ x 2HE x 600mm
LAB/SMS 8300 8.000 0 – 300 0 – 30 19“ x 2HE x 600mm
LAB/SMS 8600 8.000 0 – 600 0 – 15 19“ x 2HE x 600mm
LAB/SMS 81000 8.000 0 – 1000 0 – 8 19“ x 2HE x 600mm
LAB/SMS 81200 8.000 0 – 1200 0 – 6,7 19“ x 2HE x 600mm
LAB/SMS1020 10.000 0 – 20 0 – 500 19“ x 2HE x 600mm
LAB/SMS1035 10.000 0 – 35 0 – 350 19“ x 2HE x 600mm
LAB/SMS1045 10.000 0 – 45 0 – 250 19“ x 2HE x 600mm
LAB/SMS1070 10.000 0 – 70 0 – 175 19“ x 2HE x 600mm
LAB/SMS10150 10.000 0 – 150 0 – 75 19“ x 2HE x 600mm
LAB/SMS10300 10.000 0 – 300 0 – 40 19“ x 2HE x 600mm
LAB/SMS10600 10.000 0 – 600 0 – 17 19“ x 2HE x 600mm
LAB/SMS101000 10.000 0 – 1000 0 – 10 19“ x 2HE x 600mm
LAB/SMS101200 10.000 0 – 1200 0 – 8,4 19“ x 2HE x 600mm

 

Master- Slave for higher power

Options

Suffix Description
../3P208 i/p 3 x 208 / 187 – 229VAC
../3P400 i/p 3 x 400 / 360 – 440VAC
../3P480 i/p 3 x 480 / 432 – 528VAC
../ATE Only ATE mode, no frontpanel
../ATI5/10 Isolated analogue interface 0-5/0-10VDC set and monitor
../LT Interface IEEE 488, GPIB
../LTRS485 Interface RS 485
../LTRS232 Interface RS 232
../LAN Interface LAN
../USB Interface USB
../KFZ12 car starting curve 12VDC
../KFZ24 car starting curve 24VDC
../OPT Output characteristics
../SD SD card slot
../M-S Master-Slave Option for max. 90 kW power

 

Caratteristiche tecniche

Input Voltage Specification
Volltage Range 230 VAC/3×208 VAC/3x400VAC/3x480VAC +/-10%
Frequency 47 – 63 Hz
EMC ans Safety Standards
IT Equipment – Safety EN 60950
Emission standard
for industrial environments EN 61000-6-4
Immunity
for industrial environments EN 61000-6-2
Programming & Controls
Static Voltage Regulation +/- 0.05% + 2mV
Static Current Regulation +/- 0.1% + 2mA
Dynamic Load Regulation < 2ms (typ.)
Rippel < 0.2% (typ.)
Stability +/-0.05%
Programming Accuracy (Vout) +/- 0.05% +2mV
Isolation 3000 V
Over Voltage Protection 0 – 120% Vmax
Cuircuit Protection OC/OV/OT/OP
Line Regulation < +/- 0.1% + 2mV
Static Load Regulation < +/- 0.1% + 2mV
Output Specifications
Output Control & Monitoring Front panel and/or optional Analog 0 to +5V/+10V Standard & isolated /
Digital 12 bit: RS232, RS485, IEE-488, LAN, USB, SD card
Enviromental
Operation Temperature Range 0 – 50°C
Humidity 0 – 90% (non-condensing)
Power Reduction 50 – 70°C – 2%/°C
Storage Humidity 0 – 95% (non-condensing)
Storage Temperature Range -45°C – 85°C
Vibration 10 – 55Hz / 1min / 2G XYZ
Shock < 20G
Weight 3 – 5 kW 18 kg, 6 – 10 kW 25 kg

Alimentatori programmabili AC/DC serie LAB/HP 5 – 90 KW

Informazioni generali

Datasheet alimentatore LAB/SMS LAB/HP

• Alimentatori programmabili ad alta efficienza (fino al 94%)
• Design compatto 15kW in 3 U
• Possibilità di utilizzo in parallelo fino a 6 unità
• Interfaccia intuitiva
• Modalità: ConstantCurrent ,ConstatVoltage, ConstantResistance e ConstantPower
• Memoria per curve V/I custom con SD card esterna (es. simulazione pannelli solari e sequenza di uscita)
• Modalità VI, VIP, VIR e simulazione pannelli solari
• Script per controllo sequenziale caricabile su memory card SD (funzionamento autonomo senza PC)
• Funzione data logging a intervalli regolabili con salvataggio su memory card SD
• Display grafico
• Interfaccia analogica galvanicamente isolata 5/10 VDC per impostare e leggere i valori in uscita
• Interfacce di comunicazione disponibili: IEEE 488, RS232/485, USB e LAN
• Script control: possibilità di programmare sequenze e registare i valori in uscita su scheda SD.  Questa caratteristica permette di creari stazioni di test stand alone senza la necessità di usare PC di controllo
• Limitazione uscita massima selezionabile attarverso le variabili Vmax e Imax
• Modelli custom su richiesta

 

Modelli

Type

Power W

Voltage V

Current A

Dimensions

LAB/HP 540 5.000 0 – 40 0 -125 19” x 3HE x 620mm
LAB/HP 580 5.000 0 – 80 0 – 65 19” x 3HE x 620mm
LAB/HP 5100 5.000 0 – 100 0 – 50 19” x 3HE x 620mm
LAB/HP 5150 5.000 0 – 150 0 – 35 19” x 3HE x 620mm
LAB/HP 5300 5.000 0 – 300 0 – 17 19” x 3HE x 620mm
LAB/HP 5600 5.000 0 – 600 0 – 8,5 19” x 3HE x 620mm
LAB/HP 51000 5.000 0 – 1000 0 – 5 19” x 3HE x 620mm
LAB/HP 51200 5.000 0 – 1200 0 – 4 19” x 3HE x 620mm
LAB/HP 1040 10.000 0 – 40 0 – 250 19” x 3HE x 620mm
LAB/HP 1080 10.000 0 – 80 0 – 130 19” x 3HE x 620mm
LAB/HP 10100 10.000 0 – 100 0 – 100 19” x 3HE x 620mm
LAB/HP 10150 10.000 0 – 150 0 – 70 19” x 3HE x 620mm
LAB/HP 10300 10.000 0 – 300 0 – 34 19” x 3HE x 620mm
LAB/HP 10600 10.000 0 – 600 0 – 17 19” x 3HE x 620mm
LAB/HP101000 10.000 0 – 1000 0 – 10 19” x 3HE x 620mm
LAB/HP101200 10.000 0 – 1200 0 – 8 19” x 3HE x 620mm
LAB/HP 1540 15.000 0 – 40 0 – 375 19” x 3HE x 620mm
LAB/HP 1580 15.000 0 – 80 0 – 195 19” x 3HE x 620mm
LAB/HP 15100 15.000 0 – 100 0 – 150 19” x 3HE x 620mm
LAB/HP 15150 15.000 0 – 150 0 – 100 19” x 3HE x 620mm
LAB/HP 15300 15.000 0 – 300 0 – 50 19” x 3HE x 620mm
LAB/HP 15600 15.000 0 – 600 0 – 25 19” x 3HE x 620mm
LAB/HP 151000 15.000 0 – 1000 0 – 15 19” x 3HE x 620mm
LAB/HP 151200 15.000 0 – 1200 0 – 12 19” x 3HE x 620mm

Master- Slave for higher power

Options

Suffix Description
../3P208 i/p 3 x 208 / 187 – 229 VAC
../3P400 i/p 3 x 400 / 360 – 440 VAC
../3P480 i/p 3 x 480 / 432 – 528 VAC
../ATE Only ATE mode, no frontpanel
../ATI5/10 Isolated analogue interface 0-5/0-10VDC set and monitor
../LT Interface IEEE 488
../LTRS485 Interface RS485
../LTRS232 Interface RS232
../LAN Interface LAN
../USB Interface USB
../KFZ12 car starting curve 12VDC
../KFZ24 car starting curve 24VDC
../OPT Output characteristics
../SD SD card slot
../M-S Master-Slave Option for max. 90 kW power

 

Caratteristiche tecniche

Input Voltage Specification
Volltage Range 230 VAC/3×208 VAC/3x400VAC/3x480VAC +/-10%
Frequency 47 – 63 Hz
EMC ans Safety Standards
IT Equipment – Safety EN 60950
Emission standard
for industrial environments EN 61000-6-4
Immunity
for industrial environments EN 61000-6-2
Programming & Controls
Static Voltage Regulation +/- 0.05% + 2mV
Static Current Regulation +/- 0.1% + 2mA
Dynamic Load Regulation < 2ms (typ.)
Rippel < 0.2% (typ.)
Stability +/-0.05%
Programming Accuracy (Vout) +/- 0.05% +2mV
Isolation 3000 V
Over Voltage Protection 0 – 120% Vmax
Cuircuit Protection OC/OV/OT/OP
Line Regulation < +/- 0.1% + 2mV
Static Load Regulation < +/- 0.1% + 2mV
Output Specifications
Output Control & Monitoring Front panel and/or optional Analog 0 to +5V/+10V standard & isolated /
Digital 12 bit: Rs-232. Rs-485, IEE-488, LAN, USB, SD card
Enviromental
Operation Temperature Range 0 – 50°C
Humidity 0 – 90% (non-condensing)
Power Reduction 50 – 70°C – 2%/°C
Storage Humidity 0 – 95% (non-condensing)
Storage Temperature Range -45°C – 85°C
Vibration 10 – 55Hz / 1min / 2G XYZ
Shock < 20G
Weight 5 kW 19 kg, 10 kW 26 kg, 15 kW 33 kg