{"title":"Electrolyte Injector for Prismatic Cell","description":null,"products":[{"product_id":"msk-113-pm","title":"Automatic Vacuum Sealer Integrated w\/ Electrolyte Injection \u0026 Diffusion for Pouch Battery - MSK-113-PM","description":"\u003cp\u003eMSK-113-PM is a semi-auto three-in-one vacuum sealer with a four-position rotational platform for the stream-flow processes of pouch battery fabrication including electrolyte injection, electrolyte diffusion \u0026amp; degassing, and vacuum hot sealing. It features an air-tight chamber with a front observation window and operation gloves which allow the operation in a moisture and oxygen-free environment. In this technique, the pouch cell is loaded in station#1 following the electrolyte injection in station#2. Then, the cell will be transferred to station#3 for vacuum degassing \u0026amp; diffusion which helps with electrolyte wetting over the electrode materials. Finally, the cell will be transferred to station#4 for gas removal and hot seal under vacuum conditions. This is an ideal system for pilot-scale pouch battery manufacturing with accurate and efficient workflow.\u003cbr\u003e\u003cspan style=\"color: rgb(255, 42, 0);\" data-mce-style=\"color: rgb(255, 42, 0);\"\u003e\u003cstrong\u003eNote This machine must be operated in a dry room.\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eSPECIFICATIONS:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdvanced Features\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eA four-position rotational platform enables the continuous flow-stream process of battery cell loading, electrolyte injection, electrolyte diffusion \u0026amp; vacuum degassing, and the final vacuum hot sealing. \u003cem\u003ePlease refer to pic.1 for platform configuration.\u003c\/em\u003e\n\u003c\/li\u003e\n\u003cli\u003eFeatured an air-tight chamber with a front observation window and operation gloves. The unit provides inlet and outlet valves for continuous inert dry gas purging. It protects the cells from moisture or oxygen exposure during the process. \u003cem\u003ePlease refer to pic.2 for details.\u003c\/em\u003e\n\u003c\/li\u003e\n\u003cli\u003eTwo air-tight ante-chambers with pneumatic isolation gates are featured on the left (for cell load-in) and the right (for cell unload) sides of the chamber. \u003cem\u003ePlease refer to pic.2 for details.\u003c\/em\u003e\n\u003c\/li\u003e\n\u003cli\u003eThree entrance doors with positive latches (left, right \u0026amp; back) provide easy access to the working station adjustment and maintenance. \u003cem\u003ePlease refer to pic.3 for details.\u003c\/em\u003e\n\u003c\/li\u003e\n\u003cli\u003eA large LCD touch screen on the front enables easy control over electrolyte injection amount \u0026amp; rate, vacuum diffusion\/degassing period \u0026amp; cycles, sealing temperature \u0026amp; time. \u003cem\u003ePlease refer to pic.4 for details.\u003c\/em\u003e \u003c\/li\u003e\n\u003cli\u003eThe system is designed to use in a dry room. A regular room is also working. \u003c\/li\u003e\n\u003c\/ul\u003e\n      \u003ca rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/MSK-113-PM-2.jpg\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/MSK-113-PM-2.jpg\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/MSK-113-PM-2.jpg\" alt=\"\" width=\"107\" height=\"60\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/MSK-113-PM-2.jpg\"\u003e\u003c\/a\u003e    \u003ca rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/MSK-113-PM-3.png\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/MSK-113-PM-3.png\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/MSK-113-PM-3.png\" alt=\"\" height=\"60\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/MSK-113-PM-3.png\"\u003e\u003c\/a\u003e      \u003ca rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/MSK-113-PM-4.png\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/MSK-113-PM-4.png\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/MSK-113-PM-4.png\" alt=\"\" width=\"56\" height=\"60\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/MSK-113-PM-4.png\"\u003e\u003c\/a\u003e               \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/MSK-113-PM-1.png\" target=\"\/images\/MSK-113-PM-1.png\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/MSK-113-PM-1.png\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/MSK-113-PM-1.png\" alt=\"\" width=\"123\" height=\"60\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/MSK-113-PM-1.png\"\u003e\u003c\/a\u003e\u003cbr\u003e                   Pic.1                     Pic.2                    Pic.3                               Pic.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eThree phases AC 380 V 50 Hz\u003c\/li\u003e\n\u003cli\u003e6KW power\u003c\/li\u003e\n\u003cli\u003eThree phases AC 220V version is available upon request\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking Gas\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e0.5~0.8 Mpa high purity compressive inert gas (Ar is preferred) is required for driving the pneumatic system\u003c\/li\u003e\n\u003cli\u003e\u0026lt; -60 dew point\u003c\/li\u003e\n\u003cli\u003eContinues dry inert gas purging for the working chamber is required to maintain a dry atmosphere for electrolyte injection and diffusion \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePouch Size Adaptability\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eMax. L180*W150mm\u003c\/li\u003e\n\u003cli\u003eMin. L62*W45mm*H6mm\u003c\/li\u003e\n\u003cli style=\"color: rgb(255, 42, 0);\" data-mce-style=\"color: rgb(255, 42, 0);\"\u003e\u003cspan style=\"color: rgb(255, 42, 0);\" data-mce-style=\"color: rgb(255, 42, 0);\"\u003eLarge size is available upon request\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrolyte Dispenser\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eElectrolyte plunger metering pump is included for precise electrolyte filling (0.3% accuracy)\u003c\/li\u003e\n\u003cli\u003eFilling volume and injection rate adjustable via touch screen control\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVacuum Degassing \u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eVacuum range: -95 ~ 0 kPa adjustable\u003c\/li\u003e\n\u003cli\u003eDwell Time: 0~99 seconds adjustable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSealing Die \u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eSealing width: 4 mm (customizable)\u003c\/li\u003e\n\u003cli\u003eSealing length: ? 180 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eSeal Pressure \u003cbr\u003e\u003cem\u003e\u003cstrong\u003e\u003cem\u003e\u003cstrong\u003e\u003cem\u003e\u003cstrong\u003e\u003cem\u003e\u003cstrong\u003e\u003ca href=\"CGA-580-LD\" data-mce-href=\"CGA-580-LD\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/EQGRCGA580.jpg\" alt=\"\" width=\"71\" height=\"47\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/EQGRCGA580.jpg\"\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003e\u003cem\u003e\u003cstrong\u003e\u003cem\u003e\u003cstrong\u003e\u003cem\u003e\u003cstrong\u003epic1\u003c\/strong\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003e\u003cem\u003e\u003cstrong\u003e\u003cem\u003e\u003cstrong\u003e\u003cem\u003e\u003cstrong\u003e\u003cem\u003e\u003cstrong\u003e\u003ca href=\"ACPHD-3-LD\" data-mce-href=\"ACPHD-3-LD\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/EQACPHD3.3.jpg\" alt=\"\" width=\"78\" height=\"52\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/EQACPHD3.3.jpg\"\u003e\u003c\/a\u003e \u003c\/strong\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cem\u003e\u003cem\u003e\u003cem\u003e\u003cem\u003e\u003cem\u003e \u003c\/em\u003e\u003c\/em\u003e\u003c\/em\u003e\u003c\/em\u003e\u003c\/em\u003e\u003cem\u003e\u003cem\u003e\u003cem\u003e\u003cem\u003epic2\u003c\/em\u003e\u003c\/em\u003e\u003c\/em\u003e\u003c\/em\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003ePressure range: 0.3~0.6 Mpa adjustable.\u003c\/li\u003e\n\u003cli\u003eConsumption: ~ 0.1 L compressed air per sealing\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eAttention: If a gas cylinder is used instead of an air compressor(pic2), a two-stage pressure regulator(pic1) must be installed on the gas cylinder to limit the pressure within the required working range for safe operation. \u003ca rel=\"noopener\" href=\"CGA-580-LD\" target=\"_blank\"\u003eClick here to learn the installation of a gas regulator.\u003c\/a\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSealing Temperature\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eTwo digital temperature controllers on the front panel provide independent control for the left and right heating dies.\u003c\/li\u003e\n\u003cli\u003eTemperature range: 50 ~ 250  adjustable (accuracy +\/- 3)\u003c\/li\u003e\n\u003cli\u003eRecommended sealing temperature: 180~190\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSealing Time and Speed\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e3-4 seconds for sealing each cell only\u003c\/li\u003e\n\u003cli\u003e~ 30 secons to make electrolyte injection and sealing for each pouch cell\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVacuum Pumps (not included)\u003cbr\u003e\u003ca rel=\"noopener\" href=\"FYP-Pump\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/EQFYPmain.2.jpg\" alt=\"\" width=\"72\" height=\"48\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/EQFYPmain.2.jpg\"\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eTwo rotary vacuum pumps are needed for vacuum diffusion and degassing and vacuum sealing. Please click the picture below to purchase separately.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompliance\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eNRTL Certification is available upon request at an extra cost\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication Notes\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003ePlease clean the sealing dies after each use. Clean the sealing die after it has cooled down to avoid corrosion by the electrolyte.\u003c\/li\u003e\n\u003cli\u003eCheck the level and smoothness of sealing die surface regularly. If there is damage to the sealing die, please contact MTI to order a replacement.\u003c\/li\u003e\n\u003cli\u003eThe featured air-tight chamber enables the operation under Ar atmosphere where \u003ca rel=\"noopener\" href=\"https:\/\/mtiecommerce.myshopify.com\/blogs\/battery-research-knowledge-base\/what-is-new-in-li-s-battery-research?_pos=2\u0026amp;_sid=f61675346\u0026amp;_ss=r\" target=\"_blank\"\u003eLithium-Sulfur\u003c\/a\u003e, \u003ca rel=\"noopener\" href=\"https:\/\/mtiecommerce.myshopify.com\/search?q=Lithium+Air\u0026amp;options%5Bprefix%5D=last\" target=\"_blank\"\u003eLithium Air,\u003c\/a\u003e \u003ca rel=\"noopener\" href=\"https:\/\/mtiecommerce.myshopify.com\/blogs\/battery-research-knowledge-base\/solid-electrolyte-research?_pos=1\u0026amp;_sid=f357bc5b8\u0026amp;_ss=r\" target=\"_blank\"\u003eLithium Solid State,\u003c\/a\u003e or \u003ca rel=\"noopener\" href=\"https:\/\/mtiecommerce.myshopify.com\/search?q=Li-ion+half+cell\u0026amp;options%5Bprefix%5D=last\" target=\"_blank\"\u003eLi-ion half cell\u003c\/a\u003e will be assembled. Please click the images below to understand these technologies and how it fits in a glove box.\u003cbr\u003e\u003ca href=\"http:\/\/www.nature.com\/nmat\/journal\/v11\/n1\/fig_tab\/nmat3191_F1.html\" data-mce-href=\"http:\/\/www.nature.com\/nmat\/journal\/v11\/n1\/fig_tab\/nmat3191_F1.html\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/nmat3191-f1.jpg?v=1706307403\" alt=\"\" width=\"222\" height=\"69\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/nmat3191-f1.jpg?v=1706307403\"\u003e\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"MTI","offers":[{"title":"Default Title","offer_id":53896605040966,"sku":"MSK-113-PM","price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0533\/5600\/3482\/files\/MSK113PMMain_68531164-5188-4615-861f-8f31f0447c18.jpg?v=1736530365"},{"product_id":"msk-html-ld","title":"Compact Liquid Distributing System with 6-Channel Metering Pumps \u0026 Stream Dispensers - MSK-HTML-LD","description":"\u003cdiv\u003eMSK-HTML-LD is a compact automatic liquid distributing system that can be applied to high throughput distributing of multi-channel liquids. \u003cbr\u003eThe PLC control system with PC-Base data management allows the user to easily configure a set of programming steps and record the data. \u003cbr\u003eA three-axis platform with a precise metering pump can transfer different liquid sources from source to sample accurately and automatically according to the preset dosing scheme. \u003cbr\u003eThe desktop design enclosure can accommodate 6 dosing tubes(Standard, the sample number could be customized up to 64). \u003cbr\u003eOnce programmed, the workflow is non-stop and does not need any manual supervision. It is an excellent tool for high-throughput applications (such as LiB electrolyte pipetting workflow), without dedicated labor. \u003cbr\u003e\u003cbr\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003eMTI has granted the patent 2019SR0892401 for the High Throughput Automatic Liquid Dispensing System MSK-HTML-L since July 2019.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ctable cellpadding=\"1\" cellspacing=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFeatures\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/msk-html-ld-1.jpg\"\u003e\u003cimg height=\"60\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/msk-html-ld-1.jpg\"\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e6 Channel precise Stream Metering Pump with standard 6 sample stations. The sample number could be customized up to 64\u003c\/li\u003e\n\u003cli\u003eThe sample container\/tube is mounted on the platform fixture\/rack for program positioning\u003c\/li\u003e\n\u003cli\u003eThe source liquid container features liquid level detection;\u003c\/li\u003e\n\u003cli\u003eAuto washing function for the liquid transfer pipeline help avoid cross-contamination;\u003c\/li\u003e\n\u003cli\u003eThe type and quantity of the required ingredients and the amount of each liquid added can be edit as recipes and programmed in the software.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking Voltage\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e220VAC, single phase, 50Hz\u003c\/li\u003e\n\u003cli\u003ePower: 1 kW\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWork Station\u003c\/td\u003e\n\u003ctd\u003eXYZ triaxial module platform station\u003cbr\u003e\n\u003cul\u003e\n\u003cli\u003eX-axis: single guide slider module, the working distance is 420mm, built-in Servo motor;\u003c\/li\u003e\n\u003cli\u003eY-axis: double guide slider module, the working distance is 270mm, built-in Servo motor;\u003c\/li\u003e\n\u003cli\u003eZ-axis: rail slider module, the working distance is 140mm, built-in Servo motor.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6 channel Metering Pump with Pipetting Tips\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eMounting fixture\/rack can accommodate 6 source containers\/tubes\u003c\/li\u003e\n\u003cli\u003e6 channels liquid pipetting heads work individually in sequence, each channel can deliver 0.1mL-20mL for each move. \u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003e0.1 mL liquid injection\/delivery\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003eAccuracy: ±7 uL; \u003c\/li\u003e\n\u003cli\u003eDelivery Reproducibility (C.V.%): ± 7%\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e1 mL liquid injection\/delivery\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003eAccuracy: ± 14 uL\u003c\/li\u003e\n\u003cli\u003eDelivery Reproducibility (C.V.%): ± 1.5%\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e10 mL liquid injection\/delivery\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003eAccuracy: ± 0.1 mL\u003c\/li\u003e\n\u003cli\u003eDelivery Reproducibility (C.V.%): ± 1%\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cli\u003ePipetting Tips is easily replaceable\u003c\/li\u003e\n\u003cli\u003eThe metering pump with a PTFE liner can resist most of the acidic and alkaline-based solutions.\u003c\/li\u003e\n\u003cli\u003e6 liquid source tanks: 2 source tanks are 100 mL; 2 source tanks are 250 mL; 2 source tanks are 2,000 mL\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Container\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eStandard: 6 sample containers, each of a capacity 30 mL\u003c\/li\u003e\n\u003cli\u003eCustomized capacities 2mL - 500mL\u003c\/li\u003e\n\u003cli\u003eOptional Hot Bath: Total Six 10 W heating sources; Maximum temperature: 80°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Collection Stage\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e283 mm L x 130 mm W x 20 mm H\u003c\/li\u003e\n\u003cli\u003eUp to 64 sample containers could be customized by request at an extra cost\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDistribution Speed\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e~400 samples\/ 8 hours\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e25±3 (environmental temperature)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e30-90%RH or lower\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCleanroom classification\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e1,000,000\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Source\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eInert Gas Tank or Air Compressor (0.5~0.8Mpa) is needed for the machine operation, please purchase separately. \u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eAttention: If a gas cylinder is used instead of an air compressor(pic2), a two-stage pressure regulator(pic1) must be installed on the gas cylinder to limit the pressure within the required working range for safe operation. \u003ca href=\"CGA-580-LD\" rel=\"noopener\" target=\"_blank\"\u003eClick here to learn the installation of a gas regulator.\u003c\/a\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cem\u003e\u003cstrong\u003e\u003cem\u003e\u003cstrong\u003e \u003ca href=\"CGA-580-LD\" rel=\"noopener\" target=\"_blank\"\u003e\u003cem\u003e\u003cstrong\u003e\u003cem\u003e\u003cstrong\u003e\u003cimg height=\"52\" width=\"78\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/EQGRCGA580.jpg\"\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/a\u003e pic1 \u003cem\u003e\u003cstrong\u003e\u003cem\u003e\u003cstrong\u003e\u003ca href=\"ACPHD-3-LD\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg height=\"52\" width=\"78\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/EQACPHD3.3.jpg\"\u003e\u003c\/a\u003e pic2\u003c\/strong\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/em\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgramming \u0026amp; Softwire\u003cbr\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003ePC-based data analysis software can save the dosing data of each sample tube automatically. Data can be exported in Excel format.\u003c\/li\u003e\n\u003cli\u003eHMI programming. Each step allows the user to set the pipette movement of each source and calibrate the positioning of the sample tube racks.\u003c\/li\u003e\n\u003cli\u003eThe recipe maker allows the user to easily edit, store, and upload a protocol.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/div\u003e","brand":"MTI","offers":[{"title":"Default Title","offer_id":53903681061190,"sku":"MSK-HTML-LD","price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0533\/5600\/3482\/files\/msk-html-ld-main_c580d81e-d219-43d4-8597-894b5c5d1a2c.jpg?v=1736531272"},{"product_id":"msk-113-svm","title":"Compact Vacuum Electrolyte Injection System for Prismatic Cells - MSK-113-SVM","description":"\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eSPECIFICATIONS:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"1\" cellspacing=\"0\" cellpadding=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cpre\u003e Input Power\u003c\/pre\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eAC 208 - 240 V, 50\/60Hz, Single phase (AC 110V is available upon request)\u003c\/li\u003e\n\u003cli\u003ePower: 1KW\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cpre\u003e Electrolyte Dispenser\u003c\/pre\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eAn electrolyte plunger metering pump is included for precise electrolyte filling;\u003c\/li\u003e\n\u003cli\u003eDuring the electrolyte injection and vacuum standing under the vacuum, the liquid electrolytes would be vaporized.\u003c\/li\u003e\n\u003cli\u003ePlease consider refilling the electrolyte if necessary\u003c\/li\u003e\n\u003cli\u003eElectrolyte filling volume and injection rate adjustable via touch screen PLC control\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cpre\u003e Electrolyte Tank\u003c\/pre\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eMax. 300ml\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cpre\u003e Cell Size \u003c\/pre\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eMax. L 175 mm * W 73 mm * H 205 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cpre\u003e Injection Accuracy\u003c\/pre\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ctable border=\"1\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003caddress\u003eElectrolyte Volume (g)\u003c\/address\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003caddress\u003e5g \u003c\/address\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003caddress\u003e50g \u003c\/address\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003caddress\u003e100g\u003c\/address\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003caddress\u003eInjection Accuracy\u003c\/address\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003caddress\u003e ±2%\u003c\/address\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003caddress\u003e±1.5%\u003c\/address\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003caddress\u003e±1.2%\u003c\/address\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\nInjection Pump Speed: 100 r\/min Transfer Pump Speed: 200 r\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cpre\u003e Injection Time\u003c\/pre\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eFor prismatic cells requiring 6g electrolyte, the estimated injection time is less than 4 mins.\u003c\/li\u003e\n\u003cli\u003e(The estimated time is for reference only, the time may change subject to the actual circumstances.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cpre\u003e Prismatic Cell under Pressure\u003c\/pre\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eMaximum applied pressure 120 KPa, adjustable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cpre\u003e Vacuum Rate\u003c\/pre\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eMaximum - 95 KPa, adjustable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cpre\u003e Vacuum Pump (not included)\u003cbr\u003e\u003ca rel=\"noopener\" href=\"FYP-Pump\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/EQFYPmain.2.jpg\" alt=\"\" width=\"80\" height=\"53\"\u003e\u003c\/a\u003e\u003c\/pre\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eDouble-stage rotary vacuum pumps are needed for vacuum diffusion, degassing, and vacuum sealing.\u003c\/li\u003e\n\u003cli\u003ePlease click the picture on the left to purchase separately.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cpre\u003e Working Gas\u003c\/pre\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e0.5~0.8 MPa high purity compressive inert gas (Ar is preferred) is required for driving the pneumatic system in the glove box\u003c\/li\u003e\n\u003cli\u003eContinues dry inert gas purging for the working chamber is required to maintain a dry atmosphere for electrolyte injection and diffusion \u003c\/li\u003e\n\u003cli\u003eAir compressors and\u003ca href=\"http:\/\/www.mtixtl.com\/8mmtubesizetom-styleairplugmti-8mm-mstyle.aspx\"\u003e \u003c\/a\u003e\u003ca rel=\"noopener\" href=\"MTI-8MM-MStyle\" target=\"_blank\"\u003efitting\u003c\/a\u003e are required if used in the dry room, but not included. \u003ca rel=\"noopener\" href=\"SRS-3G-LD\" target=\"_blank\"\u003eplease click here to order \u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eAttention: If a gas cylinder is used instead of an air compressor(pic2), a two-stage pressure regulator(pic1) must be installed on the gas cylinder to limit the pressure within the required working range for safe operation. \u003ca rel=\"noopener\" href=\"CGA-580-LD\" target=\"_blank\"\u003eClick here to learn the installation of a gas regulator\u003c\/a\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cem\u003e\u003cem\u003e\u003cstrong\u003e\u003ca rel=\"noopener\" href=\"CGA-580-LD\" target=\"_blank\"\u003e\u003cem\u003e\u003cstrong\u003e\u003cem\u003e\u003cstrong\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/EQGRCGA580.jpg\" alt=\"\" width=\"65\" height=\"43\"\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/a\u003e \u003ca rel=\"noopener\" href=\"ACPHD-3-LD\" target=\"_blank\"\u003e\u003cem\u003e\u003cem\u003e\u003cstrong\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/EQACPHD3.3.jpg\" alt=\"\" width=\"66\" height=\"44\"\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/em\u003e\u003c\/a\u003e\u003cbr\u003e\u003cem\u003e\u003cem\u003e\u003cstrong\u003e    pic1              \u003c\/strong\u003e\u003c\/em\u003e\u003c\/em\u003e \u003cem\u003e\u003cem\u003e\u003cstrong\u003epic2\u003c\/strong\u003e\u003c\/em\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/em\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cpre\u003e Compliance\u003c\/pre\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eNRTL Certification is available upon request at an extra cost\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cpre\u003e Application Notes\u003cbr\u003e\u003ca rel=\"noopener\" href=\"Bal-CX220-LD\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/2.18.jpg\" alt=\"\" width=\"77\" height=\"51\"\u003e\u003c\/a\u003e\u003c\/pre\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003ePlease clean the sealing dies after each use. Clean the sealing die after it has cooled down to avoid corrosion by the electrolyte.\u003c\/li\u003e\n\u003cli\u003eThe featured air-tight chamber enables the operation under the Ar atmosphere where \u003ca rel=\"noopener\" href=\"https:\/\/mtiecommerce.myshopify.com\/blogs\/battery-research-knowledge-base\/what-is-new-in-li-s-battery-research?_pos=2\u0026amp;_sid=a04ffa342\u0026amp;_ss=r\" target=\"_blank\"\u003eLithium-Sulfur\u003c\/a\u003e, \u003ca rel=\"noopener\" href=\"https:\/\/mtiecommerce.myshopify.com\/search?q=Lithium+Air+\u0026amp;options%5Bprefix%5D=last\" target=\"_blank\"\u003eLithium Air\u003c\/a\u003e, \u003ca rel=\"noopener\" href=\"https:\/\/mtiecommerce.myshopify.com\/blogs\/battery-research-knowledge-base\/solid-electrolyte-research?_pos=1\u0026amp;_sid=21c344b57\u0026amp;_ss=r\" target=\"_blank\"\u003eLithium Solid-State\u003c\/a\u003e, will be assembled. Please click the images below to understand these technologies and how it fits in a glove box.\u003c\/li\u003e\n\u003cli\u003ePlease add the high-precision digital balance on the left to the chamber to monitor and evaluate the liquid electrolyte lost during the vacuum electrolyte injection. Because there might be some liquid electrolyte evaporation caused by the pressure difference between the liquid electrolyte tank and the vacuum chamber.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"MTI","offers":[{"title":"Default Title","offer_id":53959748190534,"sku":"MSK-113-SVM","price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0533\/5600\/3482\/files\/MSK-113-SVM-main_81a5ec7a-09a7-4d34-a535-7967abe724fd.jpg?v=1736533862"},{"product_id":"msk-115a-h","title":"Large Vacuum Sealer w\/ Electrolyte Injection and Vacuum Standing for Pouch Cell up to 500x350 mm- MSK-115A-H","description":"\u003cp\u003eMSK-115A-H is a vacuum sealer with multi-functions, including electrolyte injection, vacuum standing (electrolyte diffusion), and vacuum Sealing for large-size pouch cell batteries. This device could be used in a dry room.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eSPECIFICATIONS:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"1\" cellspacing=\"0\" cellpadding=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdvanced Features\u003cbr\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/steps.jpg\" target=\"_blank\"\u003e\u003cimg title=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/steps.jpg\" alt=\"\" width=\"94\" height=\"62\"\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eLarge or mid-size Pouch cells (EV cells) vacuum sealing, electrolyte injection, vacuum standing three-in-one design\u003c\/li\u003e\n\u003cli\u003eThe electrolyte filler with a speed control console and injection pump for the high-precision dispensing\u003c\/li\u003e\n\u003cli\u003eElectrolyte injection could be done under different vacuum levels in order to achieve a better electrode immersion\u003c\/li\u003e\n\u003cli\u003eThe built-in liquid electrolyte filtration system and vacuum pump\u003c\/li\u003e\n\u003cli\u003eVacuum sealing: high-temperature uniformity and high-consistency sealing performance\u003c\/li\u003e\n\u003cli\u003eProgrammable gas purge function is optional upon request.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eAC 208 - 240 V 50\/60 Hz Single phase\u003c\/li\u003e\n\u003cli\u003ePower: 1.5 KW\u003c\/li\u003e\n\u003cli\u003eAC 110V single-phase version is available upon request\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking Gas\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eUsed in the dry room\u003c\/li\u003e\n\u003cli\u003e0.5~0.8 Mpa high purity compressive inert dry gas (Ar is preferred) is required for driving the pneumatic system\u003c\/li\u003e\n\u003cli\u003eContinues dry inert gas purging for the working chamber is required to maintain a dry atmosphere for electrolyte injection and diffusion\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrolyte Dispenser\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eAn electrolyte plunger metering pump is included for precise electrolyte filling; Injection Accuracy: 3 ‰\u003c\/li\u003e\n\u003cli\u003eDuring the electrolyte injection and vacuum standing under the vacuum, The liquid electrolytes would be vaporized. Please consider refilling the electrolyte if necessary\u003c\/li\u003e\n\u003cli\u003eElectrolyte filling volume and injection rate adjustable via touch screen PLC control\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePouch Size Adaptability\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eMax. L 500 mm * W 350 mm * H 20 mm\u003c\/li\u003e\n\u003cli\u003eMulti-cell seal up to 500 mm in length ( for example 6 x 80 mm)\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/pouchsealing.jpg\" rel=\"zoom-id:Zoomer; caption-source:#4\" rev=\"\/images\/https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/pouchsealing.jpg\"\u003e\u003cimg title=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/pouchsealing.jpg\" alt=\"\" height=\"55px\"\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVacuum Degassing \u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eVacuum range: -95 ~ 0 kPa adjustable\u003c\/li\u003e\n\u003cli\u003eDwell Time: 0 ~ 99 seconds adjustable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHot Sealing Blade\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eSealing blade width: 10 mm (standard)\u003c\/li\u003e\n\u003cli\u003eCustomizable up to 15 mm\u003c\/li\u003e\n\u003cli\u003eSealing blade length: ? 550 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSealing Pressure \u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eMaximum sealing pressure: 0.7 MPa (500 kg*f)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSealing Temperature\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eTwo digital temperature controllers on the front panel provide independent control for the left and right heating dies.\u003c\/li\u003e\n\u003cli\u003eTemperature range: 50 ~ 250 adjustable (accuracy +\/- 2 )\u003c\/li\u003e\n\u003cli\u003eRecommended sealing temperature: 180~190 \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSealing Time\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e0 ~ 99 seconds adjustable (8 ~ 10 seconds is recommended)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompliance\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eNRTL Certification is available upon request at extra cost\u003c\/li\u003e\n\u003cli\u003eMTI has granted the patent 201822101349.0 for the Pouch Cell Sealing Machine integrated with Electrolyte Injection MSK-115A-H since December 2019.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication Notes\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003ePlease clean the sealing dies after each use. Clean the sealing die after it has cooled down to avoid corrosion by the electrolyte.\u003c\/li\u003e\n\u003cli\u003eCheck the level and smoothness of the sealing die surface regularly. If there is damage to the sealing die, please contact MTI to order a replacement.\u003c\/li\u003e\n\u003cli\u003eThe featured air-tight chamber enables the operation under the Ar atmosphere where lithium sulfur, Lithium Air, Lithium Solid-State, or Li-ion half-cells will be assembled. Please click the images below to understand these technologies and how it fits in a glove box.\u003cbr\u003e\u003ca href=\"http:\/\/www.nature.com\/nmat\/journal\/v11\/n1\/fig_tab\/nmat3191_F1.html\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/nmat3191-f1.jpg?v=1706307403\" alt=\"\" width=\"222\" height=\"69\"\u003e\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"MTI","offers":[{"title":"Default Title","offer_id":53960153891142,"sku":"MSK-115A-H","price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0533\/5600\/3482\/files\/MSK-115A-H_449827f3-8248-4edd-a057-3ba318fa3a11.png?v=1736537589"}],"url":"https:\/\/www.thasar.com\/collections\/electrolyte-injector-for-prismati-cell.oembed","provider":"Thasar S.r.l.","version":"1.0","type":"link"}