{"product_id":"2-c-bm-fc-ec-50-ml-two-compartment-bottom-mount-front-contact-electrochemical-cell-50-ml","title":"2-C BM FC EC 50 mL - Two-compartment Bottom Mount Front Contact Electrochemical Cell 50 mL","description":"\u003cp style=\"background: white; margin: 0cm 0cm 11.25pt 0cm;\"\u003e\u003cspan\u003eThis is a stationary solution two-compartment cell for measurements of a thin film deposited on a flat substrate of a specific size (variants A, B, C or D). The sample (working electrode) is placed on the piston and loaded from the bottom via screw mount, while counter and reference electrodes are mounted in a top casing (either 2-, or 3-electrode setup). The counter electrode is placed in a small glass compartment separated from the other electrodes by a ceramic frit (2 mm thick Al\u003c\/span\u003e\u003csub\u003e\u003cspan\u003e2\u003c\/span\u003e\u003c\/sub\u003e\u003cspan\u003eO\u003c\/span\u003e\u003csub\u003e\u003cspan\u003e3\u003c\/span\u003e\u003c\/sub\u003e\u003cspan\u003e nanoporous disk). This small compartment is equipped with a separate inlet and outlet for easy filling with an electrolyte and evacuation of gaseous products. After the cell is assembled the sample is sealed in the cell using the clam screw.\u003cbr\u003e\u003c\/span\u003eA customization for other substrates sizes\/shapes is available on request. The cell elements are constructed with materials that are inert to the sample (glass and PEEK). It well fits aqueous (FKM\/EPDM O-Rings) and organic solvent (FFKM O-Rings) electrolyte requirements. The construction is gas-tight and can be used when the removal and exclusion of contaminants such as oxygen and water is required by bubbling of an inert gas through the electrolyte.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication note\u003cbr\u003e\u003c\/strong\u003eThe \u003cspan style=\"color: #528ec1;\"\u003ereference electrode\u003c\/span\u003e tip should be placed close to the bottom of the chamber, where the working electrode is exposed to the electrolyte. This will ensure a negligible potential drop throughout the electrolyte solution for low-current experiment. Various auxiliary electrodes are suitable for this cell including \u003cspan style=\"color: #528ec1;\"\u003emetal wire\u003c\/span\u003e and metal foil electrodes as well as \u003cspan style=\"color: #528ec1;\"\u003egraphite rod\u003c\/span\u003e. The bubbling of gas through the solution must be stopped prior to experiment. For troubleshooting instruction see the \u003cspan style=\"color: #528ec1;\"\u003e blog post\u003c\/span\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification\u003cbr\u003e\u003c\/strong\u003esample size:\u003cbr\u003e\u003cspan\u003e  (A) 5x5 mm\u003c\/span\u003e\u003csup\u003e2\u003c\/sup\u003e\u003cspan\u003e, \u003cbr\u003e  (B) 7x7 mm\u003c\/span\u003e\u003csup\u003e2\u003c\/sup\u003e\u003cspan\u003e, \u003cbr\u003e  (C) 10x10 mm\u003c\/span\u003e\u003csup\u003e2\u003c\/sup\u003e\u003cspan\u003e, \u003cbr\u003e  (D) 15x15 mm\u003c\/span\u003e\u003csup\u003e2\u003c\/sup\u003e\u003cspan\u003e \u003cbr\u003e\u003c\/span\u003e\u003cspan\u003eacceptable sample size accuracy: +0.1 mm, -0.5 mm\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003enominal exposure area: \u003cbr\u003e   (A) 0.07 cm\u003c\/span\u003e\u003csup\u003e2\u003c\/sup\u003e\u003cspan\u003e, \u003cbr\u003e   (B) 0.2 cm\u003c\/span\u003e\u003csup\u003e2\u003c\/sup\u003e\u003cspan\u003e, \u003cbr\u003e   (C) 0.5 cm\u003c\/span\u003e\u003csup\u003e2\u003c\/sup\u003e\u003cspan\u003e, \u003cbr\u003e   (D) 1.33 cm\u003c\/span\u003e\u003csup\u003e2\u003c\/sup\u003e\u003cspan\u003e \u003cbr\u003e\u003c\/span\u003e\u003cspan\u003eminimum electrolyte volume: 25 mL\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003emaximum electrolyte volume: 45 mL\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003eelectrode plug diameter: 6 mm\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003emaximum sample thickness: 3 mm\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003enumber of electrode slots: 3\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIntrastat data\u003c\/strong\u003e\u003cbr\u003eHS Code: 90309000 \u003cbr\u003eCountry of Origin: Sweden \u003cbr\u003eNET weight: 100g\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct includes\u003cbr\u003e\u003c\/strong\u003e1 x lid\u003cbr\u003e1 x glass chamber\u003cbr\u003e1 x CE glass compartment – 0024PGLMA\u003cbr\u003e1 x bottom casing\u003cbr\u003e1 x sample screw mount\u003cbr\u003e1 x piston\u003cbr\u003e1 x clamp screw\u003cbr\u003e2 x plug\u003cbr\u003e1 x tantalum contact\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRelated products\u003cbr\u003e\u003c\/strong\u003e\u003cspan\u003eMetal Wire Auxiliary Electrode - 50HX15 0.6\/250 mm\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003eMetal Wire Auxiliary Electrode - ST 0.6\/custom\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003eSilver Chloride Reference Electrode - 70mm\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003eGraphite rod electrode - GR 6\/70 mm\u003cbr\u003eBoron-Doped Diamond plates﻿\u003cbr\u003eRhodium-plated counter electrodes\u003c\/span\u003e\u003c\/p\u003e","brand":"redox.me","offers":[{"title":"water-based electrolyte \/ (A) 5 mm x 5 mm","offer_id":56885619032390,"sku":"C-A-2C_BM_FC_EC-50-5x5","price":2237.0,"currency_code":"EUR","in_stock":true},{"title":"water-based electrolyte \/ (B) 7 mm x 7 mm","offer_id":56885619065158,"sku":"C-A-2C_BM_FC_EC-50-7x7","price":2237.0,"currency_code":"EUR","in_stock":true},{"title":"water-based electrolyte \/ (C) 10 mm x 10 mm","offer_id":56885619097926,"sku":"C-A-2C_BM_FC_EC-50-10x10","price":2237.0,"currency_code":"EUR","in_stock":true},{"title":"water-based electrolyte \/ (D) 15 mm x 15 mm","offer_id":56885619130694,"sku":"C-A-2C_BM_FC_EC-50-15x15","price":2237.0,"currency_code":"EUR","in_stock":true},{"title":"organic electrolyte \/ (A) 5 mm x 5 mm","offer_id":56885619163462,"sku":"C-O-2C_BM_FC_EC-50-5x5","price":2709.0,"currency_code":"EUR","in_stock":true},{"title":"organic electrolyte \/ (B) 7 mm x 7 mm","offer_id":56885619196230,"sku":"C-O-2C_BM_FC_EC-50-7x7","price":2709.0,"currency_code":"EUR","in_stock":true},{"title":"organic electrolyte \/ (C) 10 mm x 10 mm","offer_id":56885619228998,"sku":"C-O-2C_BM_FC_EC-50-10x10","price":2709.0,"currency_code":"EUR","in_stock":true},{"title":"organic electrolyte \/ (D) 15 mm x 15 mm","offer_id":56885619261766,"sku":"C-O-2C_BM_FC_EC-50-15x15","price":2709.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0533\/5600\/3482\/files\/1_25aee901-df52-493b-98ad-a191594fc375.png?v=1782911607","url":"https:\/\/www.thasar.com\/es\/products\/2-c-bm-fc-ec-50-ml-two-compartment-bottom-mount-front-contact-electrochemical-cell-50-ml","provider":"Thasar S.r.l.","version":"1.0","type":"link"}