{"product_id":"high-pressure-ec-25-bar-50-ml","title":"High-Pressure EC, 25 bar, 50 mL - High-Pressure Single-Compartment Electrochemical Cell","description":"\u003cp\u003eThe High-Pressure Electrochemical Cell is a sophisticated apparatus engineered to facilitate advanced research in electrochemistry under elevated pressure and temperature conditions. The cell is capable of withstanding pressures up to 25 bar and temperatures up to 200 ⁰C, allowing researchers to investigate electrochemical processes under hydrothermal conditions or using a hot pressurized environment for organic solvents as reaction media. It is a single-compartment cell that accommodates various electrode setups, including standard 2- or 3-electrode configurations and custom arrangements tailored to specific experimental requirements. The cell is designed to accommodate various electrodes and sample types, including solids, liquids, and gases, enabling comprehensive studies across different material systems. \u003cbr data-mce-fragment=\"1\"\u003eThe cell is constructed from high-quality materials such as Stainless Steel 316L (outer body), PEEK (liner), and FKM elastomer (O-rings), ensuring robustness and reliability even under harsh experimental conditions. Cell material system is compatible with the following material systems: aqueous electrolytes in a full pH range, organic solvents (sulfoxides, amides, ethers, alcohols, aromatic), organic and inorganic salts (including fluorinated anions, ammonium), gases (N\u003csub data-mce-fragment=\"1\"\u003e2\u003c\/sub\u003e, Ar, H\u003csub data-mce-fragment=\"1\"\u003e2\u003c\/sub\u003e) – PEEK, FKM O-Rings The cell is equipped with three 6 mm dia. electrode ports, two 1\/4 in. OD tube gas\/liquid inlet\/outlet, and assembly of a manometer and safety relief valve (25 bar) mounted on the cooling tower. Additionally, there is a 1\/8 in. OD port for a temperature probe inside the PEEK liner. The cell is compatible with the high-pressure working electrode, high-pressure counter electrode, and high-pressure reference electrode. Unused electrode ports can be terminated with high-pressure plug.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication note\u003c\/strong\u003e\u003cbr\u003eCatalysis plays a pivotal role in various industrial processes, from petroleum refining to pharmaceutical synthesis. Understanding catalytic mechanisms under realistic conditions is crucial for optimizing catalyst performance and developing efficient processes. The High Pressure Electrochemical Cell offers a sophisticated platform for studying catalytic reactions under elevated pressure and electrochemical environments simultaneously. The cell is typically used to investigate the effect of pressure on electrochemical kinetics and mechanisms, study the electrochemical behavior of materials under high-pressure conditions for applications in energy storage, catalysis, and corrosion, and explore novel electrode materials and electrolyte systems tailored for high-pressure electrochemical devices. \u003cbr\u003eElectrodes are not included in the cell and should be added to the quotation separately.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification\u003cbr\u003e\u003c\/strong\u003emaximum operating pressure: 25 bar\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/strong\u003etotal volume of PEEK liner: 50 mL\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/strong\u003erecommended volume of liquid: 30 - 35 mL\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/strong\u003emaximum operating temperature: 200 ⁰C\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/strong\u003eport for temperature probe: 1\/8 in. (3.175 mm)\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/strong\u003eelectrode port diameter: 6 mm\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/strong\u003enumber of electrode ports: 3\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/strong\u003eother port diameters: 1\/4 in. (6.35 mm)\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/strong\u003epressure gauge dial range: 0 - 40 bar\u003cstrong data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/strong\u003erecommended tubing: 1\/4 in. OD, 1\/8 in. ID PEEK tube\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIntrastat data\u003c\/strong\u003e\u003cbr\u003eHS Code: 90309000\u003cbr data-mce-fragment=\"1\"\u003eCountry of Origin: Sweden\u003cbr data-mce-fragment=\"1\"\u003eNET weight: 2500g\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSafety note\u003cbr\u003e\u003c\/strong\u003eThe use of a High-Pressure Electrochemical Cell involves working with equipment capable of withstanding elevated pressures and conducting experiments with potentially reactive chemicals. Ensuring safety during operation is paramount to prevent accidents and protect personnel and equipment. Below are key safety considerations to observe when using the High-Pressure Electrochemical Cell:\u003c\/p\u003e\n\u003cp\u003e1. Prior to operation, all personnel involved should receive comprehensive training on the setup, operation, and safety protocols associated with the High-Pressure Electrochemical Cell. Only trained individuals familiar with the equipment should be permitted to operate it.\u003c\/p\u003e\n\u003cp\u003e2. Adhere strictly to the specified pressure limitations of the High-Pressure Electrochemical Cell. Do not exceed the recommended pressure range to prevent over-pressurization, which could lead to equipment failure and potential hazards.\u003c\/p\u003e\n\u003cp\u003e3. Ensure that all materials, including electrodes, seals, and electrolytes, are compatible with the pressure and chemical environment inside the cell. Incompatibilities could result in leaks, corrosion, or other safety hazards.\u003c\/p\u003e\n\u003cp\u003e4. Verify that the pressure relief mechanism is in place and functioning correctly. This mechanism is crucial for safely releasing excess pressure in the event of over-pressurization.\u003c\/p\u003e\n\u003cp\u003e5. Regularly inspect the seals and connections of the High-Pressure Electrochemical Cell for signs of wear, damage, or leaks. Replace any compromised components promptly to maintain sealing integrity and prevent pressure-related accidents.\u003c\/p\u003e\n\u003cp\u003e6. Establish clear emergency procedures, including evacuation routes and protocols for handling pressure-related incidents. Ensure that all personnel are aware of these procedures and know how to respond effectively in case of emergencies.\u003c\/p\u003e\n\u003cp\u003e7. Wear appropriate Personal Protective Equipment (PPE), including safety glasses, gloves, and lab coats, when operating the High Pressure Electrochemical Cell. Additional PPE may be necessary depending on the specific experimental conditions and hazards involved.\u003c\/p\u003e\n\u003cp\u003e8. Supervise experiments closely and monitor the High-Pressure Electrochemical Cell continuously during operation. Respond promptly to any abnormalities or unexpected changes in pressure or performance.\u003c\/p\u003e\n\u003cp\u003eBy adhering to these safety guidelines and exercising caution and diligence, users can minimize risks and ensure the safe and effective operation of the High-Pressure Electrochemical Cell in the laboratory. Always prioritize safety to protect yourself, your colleagues, and the integrity of the experimental setup. \u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct includes\u003cbr\u003e\u003c\/strong\u003e1 x pressure vessel, SS 316L\u003cbr data-mce-fragment=\"1\"\u003e1 x PEEK liner 50 mL\u003cbr data-mce-fragment=\"1\"\u003e1 x PEEK lid\u003cbr data-mce-fragment=\"1\"\u003e1 x set of PEEK screws\u003cbr data-mce-fragment=\"1\"\u003e1 x cell lid, SS 316L\u003cbr data-mce-fragment=\"1\"\u003e1 x screw cup, SS 316L\u003cbr data-mce-fragment=\"1\"\u003e1 x cooling tower, SS 316L\u003cbr data-mce-fragment=\"1\"\u003e1 x manometer (0 – 40 bar)\u003cbr data-mce-fragment=\"1\"\u003e1 x safety relief valve set for 25 bar\u003cbr data-mce-fragment=\"1\"\u003e1 x 4-way union, Swagelok 1\/4 in. OD, SS 316L\u003cbr data-mce-fragment=\"1\"\u003e3 x electrode fitting, Swagelok 6 mm OD x 1\/8 in. Male NPT, SS 316L\u003cbr data-mce-fragment=\"1\"\u003e2 x fitting, Swagelok 1\/4 in. OD x 1\/8 in. Male NPT, SS 316L\u003cbr data-mce-fragment=\"1\"\u003e2 x ball valve, Swagelok 1\/4 in. OD, SS 316L\u003cbr data-mce-fragment=\"1\"\u003e1 x set of O-rings, FKM, \u003cbr data-mce-fragment=\"1\"\u003e1 x temperature probe fitting, IDEX, 1\/8 in. x 1\/4-28, SS 316L\u003cbr data-mce-fragment=\"1\"\u003e3 x connecting unit, 1\/4 in. OD, 1\/8 in. ID, 30 mm long, SS 316L\u003cbr data-mce-fragment=\"1\"\u003e2 x C-spanner 85 mm (cell opening tool)\u003cbr data-mce-fragment=\"1\"\u003e1 x PEEK plug, 6 mm dia.\u003cbr data-mce-fragment=\"1\"\u003e1 x PTFE tape\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRelated products\u003cbr\u003e\u003c\/strong\u003eHigh-pressure working electrode\u003cbr\u003eHigh-pressure counter electrode\u003cbr\u003eHigh-pressure reference electrode\u003cbr\u003eHigh-pressure plug\u003cbr\u003e\u003c\/p\u003e","brand":"redox.me","offers":[{"title":"Default Title","offer_id":56885641380166,"sku":"C-HiP_EC-25bar-50","price":10000.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0533\/5600\/3482\/files\/1_b3533d33-44e5-4a97-8b84-667b93a6b878.png?v=1782911777","url":"https:\/\/www.thasar.com\/it\/products\/high-pressure-ec-25-bar-50-ml","provider":"Thasar S.r.l.","version":"1.0","type":"link"}