{"product_id":"iss-compact-wide-integrated-spectroelectrochemical-system-compact-wide","title":"ISS Compact Wide - Integrated Spectrochemical System Compact Wide","description":"\u003cp\u003eThe Compact Line of integrated spectrochemical instruments is targeted at proof of concept and early-stage research and educational purposes. Each compact line instrument includes: Avantes Compact Line spectrometer, Avantes light source, peristaltic pump, a mount for a dedicated spectroelectrochemical cell (cuvette with post) and electrolyte reservoir that are fixed on a 30 cm x 45 cm solid aluminium optical board. The components are selected, and the design is optimised to ensure a small footprint, ease of use, good analytical performance and safety when operating under a laboratory fume hood.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eCentral to the system is an optical fibre coupled spectroelectrochemical cell selected from a variety of products \u003cspan style=\"color: #1ea185;\" data-mce-style=\"color: #1ea185;\"\u003e(added separately)\u003c\/span\u003e. By using optical fibres terminated in collimating lenses both easy assembly and reproducible alignment are achieved.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eElectrolyte is delivered to the cell from a reservoir via a \u003c\/span\u003eperistaltic pump\u003cspan\u003e. The \u003c\/span\u003epump\u003cspan\u003e head has 1 channel and pumps the electrolyte at a flow rate between 0.07 up to 380 ml per minute via \u003c\/span\u003e\u003cspan\u003eS\u003c\/span\u003e\u003cspan\u003eilicone or \u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003eViton™\/Fluran™ F-5500-A\u003c\/span\u003e\u003cspan\u003e (aqueous electrolyte) or\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003ePharMed™\u003c\/span\u003e\u003cspan\u003e (organic electrolyte) internal tubing, and FEP tubing further on to the cell\/reservoir. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eSpectrometric analyses are carried out via fibre coupled Avantes Compact Line spectrometer(s) and light source(s). Preconfigured integrated systems in the UV, Vis, NIR, Wide range UV-Vis and Dual Channel ‘extra wide’ UV-VIS-NIR regions are available. These preconfigured systems match light source, fibre optic, lenses and spectrometer configurations to deliver optimised performance within the specified spectral range and analytical application, but custom systems can be configured at extra cost to meet exacting end use requirements. Please contact for additional information about custom spectrometer and instrument configurations.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eAll light sources used in the integrated systems are equipped with TTL shutters or triggers to reduce light exposure of the sample to an absolute minimum. The sources are triggered by the same software as the spectrometer allowing for simple experiment design and synchronised measurements at user defined parameters and intervals. Through the use of TTL shutters and\/or pulsed sources it is possible to both minimise undesirable thermal effects and ensure a stable light source to minimise drift.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eThe fibre optics are selected to minimise spectral absorption and optimise coupling of the light source and spectrometer thereby maximising the useable light delivered to the cell without saturating the spectrometer. This allows for faster integration times and increased signal averaging to improve the signal to noise ratio of the measurements.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eThe Compact Line systems are supplied with Avasoft Full version 8.11 plus the chemometrics extension for simple data acquisition and post processing as well as process monitoring and real-time calculation of analyte concentration. Additional Avantes software modules such as Thin Film analysis and colourimetry are available for other applications at an additional cost.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication note\u003cbr\u003e\u003c\/strong\u003eThe Integrated Spectrochemical System Compact Wide (ISS Compact Wide) includes a AvaSpec-Mini2048CL-UVI25 spectrometer and an AvaLight-XE pulsed xenon lamp coupled to the electrochemical flow cell by Low OH SMA 905 terminated optical fibres. It provides sufficient resolution and sensitivity over a large range covering the UV-Vis and NIR spectral regions from 200 to 1100 nm. It is targeted at educational labs and proof of concept research where either the spectral region of interest is not known or high spectral resolution is not required.\u003c\/p\u003e\n\u003cp\u003eThe following cells are compatible with ISS Compact Wide (\u003cspan style=\"color: #1ea185;\" data-mce-style=\"color: #1ea185;\"\u003eplease select desired option and add it to the quotation separately\u003c\/span\u003e):\u003cbr\u003eCell 1: SPECTRO-EFC, SMA 905, 1.75 mL\u003cbr\u003eCell 2: SPECTRO-EFC, 4 mm path, 0.7 mL, SMA 905 variant\u003cbr\u003eCell 3: R\/T\/A SPECTRO-EC, 1.75 mL, SMA 905 variant\u003c\/p\u003e\n\u003cp\u003eThe AvaLight-XE is a compact pulsed xenon light suitable for UV and Visible applications or for fluorescence spectroscopy of analytes in the electrolyte or at electrode surfaces. The 15 pin sub-D connector, TTL levels allows for communication to the Avantes compact line spectrometer and triggered control of pulse rate and duration.\u003c\/p\u003e\n\u003cp\u003eThe AvaSpec CompactLine spectrometers are compact and rugged spectrometers suitable for harsh environments. They deliver the resolution, sensitivity and stability that is expected from Avantes spectrometers in a form factor that is the size of a deck of cards. The AvaSpec-Mini2048CL-UVI25 is a multi-purpose instrument covering the UV through the Vis to the NIR region. When compared to either the Compact UV or Compact Vis, this configuration trades resolution for range, but its resolution of 1.3 nm over a 900 nm range (200 – 1100 nm) is sufficient for educational labs, early stage research or labs that routinely wish to probe this 900 nm range in a single instrument.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification\u003cbr\u003e\u003c\/strong\u003e\u003cem\u003eLight source: AvaLight-XE\u003cbr\u003e\u003c\/em\u003espectral output: 200 – 1000 nm\u003cem\u003e\u003cbr\u003e\u003c\/em\u003etotal optical power output: 39 µJ per pulse (average 66 mW)\u003cbr\u003eoptical power in 200 µm fibre: 0.66 µJ per pulse (average 20 µW)\u003cbr\u003eoptical power in 600 µm fibre: 3.2 µJ per pulse (average 320 µW)\u003cbr\u003eoptical power in 1000 µm fibre: 7.4 µJ per pulse (average 744 µW) \u003cbr\u003esynchronization input: 15 pin sub-D connector, TTL level\u003cbr\u003epulse duration: 5 µs (at 1\/3 height)\u003cbr\u003epulse delay: 6 µs\u003cbr\u003epulse rate (max.): 100 Hz\u003cbr\u003ebulb life (min.): 10\u003csup\u003e9\u003c\/sup\u003e pulses\u003cbr\u003econnector: SMA-905 connector\u003cbr\u003epower requirement: 12 VDC\/550 mA\u003cbr\u003edimensions, weight: 175 x 110 x 44 mm, 540 grams\u003cem\u003e\u003cbr\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eSpectrometer: AvaSpec-Mini2048CL-UVI25\u003c\/em\u003e\u003cbr\u003erange: 200 – 1100 nm\u003cbr\u003eresolution: 1.3 nm\u003cbr\u003efocal length: symmetrical Czerny-Turner, 75 mm focal length, MK II\u003cbr\u003egrating: 300 lines\/mm\u003cbr\u003eentrance slit: 25 µm\u003cbr\u003edynamic range: 3300\u003cbr\u003esignal\/noise: 330:1\u003cbr\u003eexposure time range: 30 µs to 40 s\u003cbr\u003estray light: 0.2 - 1%\u003cbr\u003esensitivity: 337,500\u003cbr\u003edetector: HAM S11639, CMOS linear array, 2048 pixels (14x200 μm)\u003cbr\u003eA\/D converter: 16-bit, 6 MHz\u003cbr\u003eoptical interface: SMA connector\u003cbr\u003eI\/O: 5 bidirectional programmable I\/O; 1 analogue out; 1 analogue in, 1x5V\u003cbr\u003einterface: USB 2.0 (480 Mbps) \/ pigtailed (40 cm) USB-A\u003cbr\u003edimensions, weight: 95 x 68 x 20 mm, 175 g\u003cbr\u003e\u003cbr\u003e\u003cem\u003eLight source to cell optical fibre\u003c\/em\u003e\u003cbr\u003etype: 0.39 NA pure silica core and TECS hard cladding, step-index, multimode fibre\u003cbr\u003e termination: dual SMA 905, \u003cbr\u003e\u003cspan data-mce-fragment=\"1\"\u003ecoating: \u003c\/span\u003eTefzel\u003cbr\u003ereinforcement: 5.0 mm stainless steel \u003cbr\u003efibre: FT600EMT Low OH pure silica core for Visible-NIR \u003cbr\u003etransmission: 400 - 2200 nm\u003cbr\u003elength: 100 cm\u003cbr\u003ecore diameter: 600 \u003cspan data-mce-fragment=\"1\"\u003e±\u003c\/span\u003e 10 µm\u003cbr\u003enumeric aperture: 0.39\u003cbr\u003ecladding diameter: 630 \u003cspan data-mce-fragment=\"1\"\u003e±\u003c\/span\u003e 10 µm\u003cbr\u003ecoating diameter: 1040 \u003cspan data-mce-fragment=\"1\"\u003e±\u003c\/span\u003e 30 µm\u003cbr\u003ebend radius short term\/long term: 30 mm\/60 mm\u003cbr\u003e\u003cbr\u003e\u003cem\u003eCell to spectrometer optical fibre\u003cbr\u003e\u003c\/em\u003etype: 0.22 NA pure silica core and double-clad TECS hard cladding over fluoride-doped silica cladding, step-index multimode fibres\u003cbr\u003e\u003cspan\u003etermination: dual SMA 905, \u003c\/span\u003e\u003cbr\u003e\u003cspan data-mce-fragment=\"1\"\u003ecoating: \u003c\/span\u003e\u003cspan\u003eTefzel\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003ereinforcement: \u003c\/span\u003e\u003cspan\u003e5.0 mm stainless steel\u003c\/span\u003e\u003cbr\u003efibre: FG200LCC Low OH pure silica core for UV – Visible Transmission 400 - 2200 nm\u003cbr\u003ecore diameter: 200 \u003cspan data-mce-fragment=\"1\"\u003e±\u003c\/span\u003e 8 µm\u003cbr\u003elength: 100 cm\u003cbr\u003enumeric aperture: 0.22\u003cbr\u003ecladding diameter: 240 \u003cspan data-mce-fragment=\"1\"\u003e±\u003c\/span\u003e 5 µm\u003cbr\u003ecoating diameter: 260 \u003cspan data-mce-fragment=\"1\"\u003e±\u003c\/span\u003e 6 µm\u003cbr\u003ebend radius short term\/long term: 12 mm \/ 24 mm\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIntrastat data\u003c\/strong\u003e\u003cbr\u003eHS Code: 90273000\u003cbr\u003eCountry of Origin: Sweden\u003cbr\u003eNET weight: 11000 g\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct includes\u003cbr\u003e\u003c\/strong\u003e1 x spectrometer - AvaSpec-Mini2048CL-UVI25\u003cbr\u003e1 x light source - AvaLight-XE\u003cbr\u003e1 x optical fibre - FT600EMT Low OH pure silica core\u003cbr\u003e1 x optical fibre - FG200LCC Low OH pure silica core\u003cbr\u003e1 x peristaltic pump with tubbing\u003cbr\u003e1 x reservoir 50 mL\u003cbr\u003e1 x aluminium breadboard, 300 mm x 450 mm x 12.7 mm, M6 Taps with rubber legs and bridge handles\u003cbr\u003e1 x PTFE cuvette\u003cbr\u003e1 x PTFE\/PEEK post 1\/4\" 20 UNC to M6\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRelated products\u003cbr\u003e\u003c\/strong\u003eFlow Cells\u003c\/p\u003e","brand":"redox.me","offers":[{"title":"Default Title","offer_id":56885647442246,"sku":"INS-ISS_COMPACT_WIDE","price":13000.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0533\/5600\/3482\/files\/1_47f6a796-8103-4344-b11e-c73f373f5791.png?v=1782911785","url":"https:\/\/www.thasar.com\/it\/products\/iss-compact-wide-integrated-spectroelectrochemical-system-compact-wide","provider":"Thasar S.r.l.","version":"1.0","type":"link"}