{"product_id":"jacketed-standard-electrochemical-cell-200-ml","title":"Jacketed Standard Electrochemical Cell","description":"\u003cp\u003eThis is a stationary solution jacketed standard electrochemical (electrolytic) cell for measurements of electrodes in a form of: a) rod\/disc (6 mm dia.), b) thin film deposited on flat substrate (using a sample holder) and c) membrane (using a clip electrode). The working, counter and reference electrodes are mounted in a top casing either in 2-, or 3-electrode setup. A temperature of an electrolyte can be controlled by circulation of a fluid agent between thermostatic bath and the jacketed vial. The cell has two spare ports for connection of \u003cem\u003ee.g.\u003c\/em\u003e thermometer, Clark electrode, pH meter electrode, or other 6 mm dia. electrode\/probe. \u003cbr\u003eThe cell elements are constructed with materials that are inert to the sample (glass and PEEK). It well fits aqueous (FKM\/EPDM O-Rings) and organic solvent (FFKM O-Rings) electrolyte requirements. The construction is gas-tight and can be used when the removal and exclusion of contaminants such as oxygen and water is required by bubbling of an inert gas through the electrolyte. The non-jacketed model is available here.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication note\u003c\/strong\u003e\u003cbr\u003eThe reference electrode tip should be placed close to a working electrode center. This will ensure a low potential drop throughout the electrolyte solution for low-current experiment. Various auxiliary electrodes are suitable for this cell including metal wire and metal foil electrodes as well as graphite rod. The bubbling of gas through the solution must be stopped prior to experiment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Video Manual:\u003cbr\u003e\u003ciframe title=\"YouTube video player\" src=\"https:\/\/www.youtube.com\/embed\/ge2VVcWcT3w\" height=\"315\" width=\"560\" allowfullscreen=\"\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" frameborder=\"0\"\u003e\u003c\/iframe\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification\u003cbr\u003e\u003c\/strong\u003emaximum electrolyte volume: 100, 150, 200, 250, 350, 500 or 1000 mL\u003cbr\u003eelectrode plug diameter: 6 mm\u003cbr\u003enumber of electrode ports: 5\u003cbr\u003evial material: borosilicate 3.3 glass\u003cbr\u003ehose connector type: multi barb\u003cbr\u003erecommended tube size: ID 8.0 mm\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIntrastat data\u003c\/strong\u003e\u003cbr\u003eHS Code: 90309000 \u003cbr\u003eCountry of Origin: Sweden \u003cbr\u003eNET weight: 100g (100, 150 mL), 200g (200, 250, 350 mL), 500g (500 mL), 1000g (1000 mL)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct includes\u003cbr\u003e\u003c\/strong\u003e1 x lid\u003cbr\u003e2 x adjustable handle\u003cbr\u003e1 x jacketed vial\u003cbr\u003e1 x working electrode mount\u003cbr\u003e3 x plug\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRelated products\u003cbr\u003e\u003c\/strong\u003eReference Electrodes \u003cbr\u003eMetal Wire Auxiliary Electrodes\u003cbr\u003eNon-metal Electrodes\u003cbr\u003eHolders and Adapters\u003c\/p\u003e","brand":"redox.me","offers":[{"title":"water-based electrolyte \/ 100 mL","offer_id":56885647638854,"sku":"C-A-STD_EC-100-J","price":525.0,"currency_code":"EUR","in_stock":true},{"title":"water-based electrolyte \/ 150 mL","offer_id":56885647671622,"sku":"C-A-STD_EC-150-J","price":788.0,"currency_code":"EUR","in_stock":true},{"title":"water-based electrolyte \/ 200 mL","offer_id":56885647704390,"sku":"C-A-STD_EC-200-J","price":1187.0,"currency_code":"EUR","in_stock":true},{"title":"water-based electrolyte \/ 250 mL","offer_id":56885647737158,"sku":"C-A-STD_EC-250-J","price":1313.0,"currency_code":"EUR","in_stock":true},{"title":"water-based electrolyte \/ 350 mL","offer_id":56885647769926,"sku":"C-A-STD_EC-350-J","price":1449.0,"currency_code":"EUR","in_stock":true},{"title":"water-based electrolyte \/ 500 mL","offer_id":56885647802694,"sku":"C-A-STD_EC-500-J","price":1575.0,"currency_code":"EUR","in_stock":true},{"title":"water-based electrolyte \/ 1000 mL","offer_id":56885647835462,"sku":"C-A-STD_EC-1L-J","price":1712.0,"currency_code":"EUR","in_stock":true},{"title":"organic electrolyte \/ 100 mL","offer_id":56885647868230,"sku":"C-O-STD_EC-100-J","price":956.0,"currency_code":"EUR","in_stock":true},{"title":"organic electrolyte \/ 150 mL","offer_id":56885647900998,"sku":"C-O-STD_EC-150-J","price":1218.0,"currency_code":"EUR","in_stock":true},{"title":"organic electrolyte \/ 200 mL","offer_id":56885647933766,"sku":"C-O-STD_EC-200-J","price":1617.0,"currency_code":"EUR","in_stock":true},{"title":"organic electrolyte \/ 250 mL","offer_id":56885647966534,"sku":"C-O-STD_EC-250-J","price":1743.0,"currency_code":"EUR","in_stock":true},{"title":"organic electrolyte \/ 350 mL","offer_id":56885647999302,"sku":"C-O-STD_EC-350-J","price":1880.0,"currency_code":"EUR","in_stock":true},{"title":"organic electrolyte \/ 500 mL","offer_id":56885648032070,"sku":"C-O-STD_EC-500-J","price":2006.0,"currency_code":"EUR","in_stock":true},{"title":"organic electrolyte \/ 1000 mL","offer_id":56885648064838,"sku":"C-O-STD_EC-1L-J","price":2142.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0533\/5600\/3482\/files\/1_5dada6e5-b7ba-4b57-9065-57ad13d792a2.png?v=1782911788","url":"https:\/\/www.thasar.com\/it\/products\/jacketed-standard-electrochemical-cell-200-ml","provider":"Thasar S.r.l.","version":"1.0","type":"link"}