{"product_id":"raman-ec-flow-cell-attachment-for-spe-holder","title":"Raman EC Flow Cell Attachment for SPE holder","description":"\u003cp\u003e\u003cspan\u003eThis setup combines two classical analytical techniques such as electrochemistry using Screen-Printed Electrodes and Raman spectroscopy, to obtain \u003c\/span\u003e\u003cem\u003ein-situ\u003c\/em\u003e\u003cspan\u003e chemical information about the reactions taking place during an electrochemical experiment. \u003c\/span\u003e\u003cspan\u003eDuring an experiment Raman laser is focused onto the surface of a thin film working electrode through a transparent S\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003eapphire (or quartz) \u003c\/span\u003e\u003cspan\u003ewindow and thin layer of electrolyte (total optical path of 3 mm). The electrolyte thickness of 2 mm ensures free diffusion of ions (e.g. protons) and their counter ions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe assembled set consisting of Screen-Printed Electrode Holder, Raman EC Flow Cell Attachment and the reservoir is gas- and liquid-tight. The reservoir is composed of Basic Electrochemical Cell (BEC 50 mL) with two additional plugs. It enables further analysis of the solution or conducting reference electrochemical measurement using classical electrodes (6 mm dia., not included in the set). The attachment elements are constructed with materials that are chemically resistive to a wide range of electrolytes (PEEK, PFA\/ETFE). Other materials such as PTFE, Titanium, Stainless Steel, etc., are available on request. The Flow Cell Attachment well fits aqueous (EPDM O-Rings) and organic solvent (FFKM O-Rings) electrolyte requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication note\u003cbr\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003eThis cell can be used to track kinetic phenomena such as the near-surface proton concentration changes during oxidation and reduction reaction at working electrode. It can be also used to identify materials such as carbon, metal oxides, polymers and electrolytes, and to determine their structure and distribution. \u003c\/span\u003eThe Raman EC Flow Cell Attachment is installed on the guide rails of the Screen-Printed Electrode Holder. The tubing is connected to the peristaltic pump (not included in the set) which drives the fluid from the reservoir through the cell (above the electrode assembly) and then returns it to the reservoir.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Video Manual:\u003cbr\u003e\u003ciframe title=\"YouTube video player\" src=\"https:\/\/www.youtube.com\/embed\/mcpHWwgXw0M\" height=\"315\" width=\"560\" allowfullscreen=\"\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" frameborder=\"0\"\u003e\u003c\/iframe\u003e\u003cbr\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/H8su7eJxDyY\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen=\"\"\u003e\u003c\/iframe\u003e\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification\u003cbr\u003e \u003c\/strong\u003etubing size: 1\/16\" OD x.040\" ID (1.6mm OD x 1.0mm ID)\u003cstrong\u003e\u003cbr\u003e \u003c\/strong\u003emaximum electrolyte volume in the reservoir: 40 mL\u003cbr\u003e electrode plug diameter in the reservoir: 6 mm\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIntrastat data\u003c\/strong\u003e\u003cbr\u003eHS Code: 90275000\u003cbr\u003eCountry of Origin: Sweden\u003cbr\u003eNET weight: 100 g (attachment only), 200 g (attachment with SPE holder)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct includes\u003cbr\u003e \u003c\/strong\u003e1 x Raman EC flow chamber with fittings\u003cbr\u003e 1 x reservoir (BEC 50 mL + 2 additional plugs)\u003cbr\u003e 1 x set of O-Rings\u003cbr\u003e 1 x Screen-Printed Electrode Holder (as variant)\u003c\/p\u003e","brand":"redox.me","offers":[{"title":"aqueous electrolyte \/ attachment only","offer_id":56885666775366,"sku":"H-A-RAM_SPE","price":1386.0,"currency_code":"EUR","in_stock":true},{"title":"aqueous and organic electrolyte \/ attachment only","offer_id":56885666808134,"sku":"H-O-RAM_SPE","price":1523.0,"currency_code":"EUR","in_stock":true},{"title":"aqueous electrolyte \/ attachment with SPE holder","offer_id":56885666840902,"sku":"H-A-RAM_SPE+HOLD","price":2657.0,"currency_code":"EUR","in_stock":true},{"title":"aqueous and organic electrolyte \/ attachment with SPE holder","offer_id":56885666873670,"sku":"H-O-RAM_SPE+HOLD","price":2898.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0533\/5600\/3482\/files\/1_bf35ded0-2704-4d05-b2f7-d522053cccbd.png?v=1782911889","url":"https:\/\/www.thasar.com\/products\/raman-ec-flow-cell-attachment-for-spe-holder","provider":"Thasar S.r.l.","version":"1.0","type":"link"}