MTI  |  SKU: IMCS-1700GB

2000ºC Max. Induction Melting System in Glove Box with O2 & H2O < 1 ppm - IMCS-1700GB

Regular price €0,00


Delivery and Shipping to EU

We will add in the quotation, the shipping, insurance, customs clearance costs.

2000ºC Max. Induction Melting System in Glove Box with O2 & H2O < 1 ppm - IMCS-1700GB

MTI

Overview

The IMCS-1700GB is an induction melting furnace integrated with a glove box. It consists of an induction power supply, a temperature control system, and a glove box. Utilizing electromagnetic induction heating, the system can quickly achieve the desired experimental temperatures. IMCS-1700GB is designed for melting and processing air-sensitive metallic alloys.

Specifications

Feature Combined with VGB-6 glove box with gas purification system and automatic purging function to ensure both oxygen and humidity are less than 1 PPM throughout the system, with a maximum vacuum level of 100 Pa.
15 kW induction power supply surrounds the quartz tube for melting under an inert gas atmosphere with precise temperature control.
Graphite is used for the crucible and insulation layers.
Quartz Chamber Dimensions: Ø130 mm (OD) × Ø122 mm (ID) × 280 mm.
Structure The 5" quartz tube with a vacuum-sealed stainless steel flange is built on the bottom of the standard glove box.
Power Supply: AC 220V, single phase, 50 Hz for VGB-6.
Output Power: 1.7 kW for VGB-6.
304 stainless steel shell with two HEPA dust filters (filtering particles ≥ 0.3 µm).
Purification Cylinder: BASF deoxygenation material and UOP dehumidification materials.
Water Probe: MICHELL (USA), 0–1000 ppm, touchscreen display, accuracy ±0.1 ppm.
Oxygen Transmitter: Bosch (Germany), 0–1000 ppm, touchscreen display, accuracy ±0.1 ppm.
Pressure Sensor: Setra (USA), -2500 to 2500 Pa, touchscreen display, accuracy ±1 Pa.
Equipped with a two-stage rotary vane vacuum pump with oil mist filter.
Induction Heating 15 kW induction power supply included.
Power Supply: AC 220V, three phase, 60 Hz.
Maximum Output Power: 15 kW.
Insulation Layers: Three-layer structure (graphite felt, alumina, high-temperature felt).
The induction coil surrounds the outside of the 5" quartz tube to heat the crucible inside.
Coil Dimensions: 156 mm (OD) × 140 mm (ID) × 90 mm (H).
Protective Shield: Three tempered glass panels surrounding the quartz chamber.
Cooling Fans: Four fans for enhanced heat dissipation.
Cooling Water Requirements: ≥0.2 MPa, ≥6 L/min.
Chamber and Sealed Flange Ø130 mm (OD) × Ø122 mm (ID) × 280 mm quartz furnace tube included.
Lower Flange: Stainless steel flange with needle valve and KF-25 vacuum port fixed to the furnace frame.
Upper Flange: Hinged type with 1/4" thermocouple feedthrough, needle valve, and barbed fitting.
Stainless steel chamber is optional for melting, casting and stirring upon request.
Note: The vacuum pump is not necessary because the glove box purification system maintains O2 and H2O below 1 PPM in the quartz tube.
Crucible & Refractory Liners High Purity Graphite Crucible: 50.8 mm (OD) × 40 mm (ID) × 115 mm (H), with lid. Maximum capacity: 50% of crucible volume.
The 2" graphite crucible is inserted inside the induction coil for sample melting.
The fibrous alumina layer surrounds the crucible for thermal insulation.
Three-layer special design refractory liner keeps the quartz temperature below 200°C.
Notes:
Graphite crucible is a consumable.
Customized graphite crucibles are available upon request.
BN liner is available upon request to avoid sample contamination from graphite.
For low melting point alloys (MP < 600°C), stainless steel (SS316) is a better choice and is available upon request.
Temperature Control System & Thermocouple Precision PID-controlled digital temperature system with up to 28 programmable segments and C-type thermocouple (Ø6.35 mm × 400 mm L).
Protection Features: Overheat and thermocouple failure safeguards.
Temperature Accuracy: ±3°C.
Heating Temperature Range: 800–1600°C (continuous); 2000°C (up to 30 minutes).
Heating Rates:
Room temperature to 1000°C: ≤1°C/s.
1000°C to 1600°C: ≤1°C/2s.
1600°C to 2000°C: ≤1°C/4s.
Recirculation Water Chiller (Optional) Recirculating water chiller with 15 L/min flow rate and 12 L capacity is available upon request.
Built-in digital temperature control and alerts.
Vacuum System (Optional) NRTL Certified 156 L/min Double Stage Rotary Vane Vacuum Pump with Exhaust Filter available upon request.
Communication Port: KF25 connection.
Compliance NRTL (UL6101) Certification available upon request at additional cost.
Application Notes A two-stage pressure regulator must be installed on the gas cylinder to limit pressure below 6 bar for safe operation.
Maximum internal pressure: 0.02 MPa.
Regularly perform regeneration to maintain optimum purification efficiency.
The O2 sensor is consumable with an expected lifespan of approximately one year. Replacement sensors are available at additional cost.
Avoid using flammable, explosive, or toxic gases unless proper safety measures are in place.
During experiments, ensure inert gas protection to prevent damage to the graphite crucible and thermocouple.
Dimensions Main Equipment: 1900mm x 1620mm x 1860mm (L x W x H)
Induction Power Supply Main Unit: 520 mm x 260 mm x 370 mm (L x W x H)
Induction Power Supply Subunit: 460mm x 260mm x 370 mm (L x W x H)
Net weight: 630kg (including glove box)