Scribner

600 PEM Electrolyzer test system

Regular price €0,00


Delivery and Shipping to EU

We will add in the quotation, the shipping, insurance, customs clearance costs.

600 PEM Electrolyzer test system

Scribner

The 600 PEM Electrolyzer Test System (ETS) is a next-generation, high-performance bench-top test system engineered for in-depth research and development of Proton Exchange Membrane (PEM) water electrolysis. This all-in-one solution delivers unmatched precision, control, and safety for the diagnostic evaluation a single electrolysis cell.

Equipped with a fully integrated Power Supply, Potentiostat, and Impedance Analyzer (supporting both EIS and HFR), the 600 ETS also features real-time sensors for Product Flow Rate and Cross-over Monitoring, providing researchers with critical insights at every stage of testing.

Our 2nd generation advancements expands automated features to support your long-term testing, and is high-pressure ready!

 

  • Integrated 100A Power Supply with EIS & HFR — Seamlessly combine electrochemical impedance spectroscopy (EIS) and high-frequency resistance (HFR) for comprehensive insights.

  • Half Cell (R1/R2) Measurements in Power Supply Mode — Get accurate data effortlessly. Our system simplifies half-cell measurements.

  • Dual Channel Mass-Flow Controller (MFC) — Say goodbye to manual rotameters! Our MFC ensures precise gas flow control, with automated safety interventions.

  • Streamlined Cell Cabling —We’ve redesigned the front panel for a simpler, more efficient cabling arrangement.

  • Single USB Connection — Connect effortlessly. One cable, one clear bench.

  • Automated Tank Refill — Unattended operation for electrolyte experiments is now a reality. Let our system handle the details.

  • DI Water Conductivity Probes —Monitor conductivity inside the feed tank via front panel displays and collect data in our FlowCell software.

  • Self-Draining Condensation Tanks — Boost automation and reduce maintenance. No more manual draining.

  • Constant voltage or current testing

  • Step/stair profiles

  • Cyclic and linear scan routines

  • Custom test protocols tailored for PEM, AEM, or alkaline electrolyzer characterization



  • Power Supply Max Current – 100A
  • Voltage Range – 0-5.000V DC
  • Maximum Power – 500W
  • Potentiostat Current Ranges – ±20 / 7 / 0.7 / 0.07A
  • Current Resolution – 0.007% of range
  • Current Limit of Error – ±1.0% of range
  • Set & Read Voltage – >±5.000V
  • Cell Voltage Sense Lead – Differential
  • Sense Lead Input Resistance – 1.0GΩ
  • Modes of Operation – Constant, Scan, Step-Stair; V and I
  • Impedance Frequency Range – 1 mHz to 10 kHz
  • Impedance Measurement Types – Sweep EIS and Single-Freq HFR Real-Time Measurement, Whole Cell and Aux

 

 

  • Operating Temperature – 5-35º C
  • Power Source – 100-120 or 220-240 VAC 50/60 Hz
  • Size (excluding tubing connections) – 53 cm x 53 cm x 100 cm (21 x 21 x 39.5 in)
  • Weight (empty) – 45 kg (100 lbs)

 

  • Robust – Embedded Firmware Level Decisions
  • Fail Safe Design – N2 Purge On Alarm Condition
  • Continuous Monitoring – E-Stop, Voltage, Current, Temperate, Gas, Contamination & External Signals

 

Included with every Scribner is a set of parts and tools for installing the instrument. Specifically, each 600 includes;

  • Tools
    • 2 wrenches, 1/2″ & 9/16″, for common fittings
  • Document Folder
    • USB drive with documentation and software
    • Calibration information
  • Cabling
    • Country specific power cords bringing wall power to unit
    • USB cable connecting Unit to Computer
    • Voltage sense cable
    • Alarm Accessory Cable
  • Extra Parts
    • DI Water Filter Kit
    • SS braided PTFE Hoses
    • Nuts and ferrules for hoses x8
    • Alligator clips x6
    • ¼” nuts, bolts, and washers for bus bars x2
    • Type T Thermocouple connectors x6
    • Analog connector Plugs x6

 

Adds extra corrosion resistance to the feed stock tanks by coating 316SS in durable Teflon™.

 

Adds Cleaned for Oxygen Service tubing and fittings on the oxygen side of the product flow path.

Ensure No Organic Contaminates which can act as fuels in oxygen rich environments.

 