600 PEM Electrolyzer test system
Delivery and Shipping to EU
Delivery and Shipping to EU
We will add in the quotation, the shipping, insurance, customs clearance costs.
600 PEM Electrolyzer test system
Scribner
The 600 PEM Electrolyzer Test System (ETS) is a next-generation, high-performance bench-top test system engineered for in-depth research and development of Proton Exchange Membrane (PEM) water electrolysis. This all-in-one solution delivers unmatched precision, control, and safety for the diagnostic evaluation a single electrolysis cell.
Equipped with a fully integrated Power Supply, Potentiostat, and Impedance Analyzer (supporting both EIS and HFR), the 600 ETS also features real-time sensors for Product Flow Rate and Cross-over Monitoring, providing researchers with critical insights at every stage of testing.
Our 2nd generation advancements expands automated features to support your long-term testing, and is high-pressure ready!
- Power Supply Max Current – 100A
- Voltage Range – 0-5.000V DC
- Maximum Power – 500W
- Potentiostat Current Ranges – ±20 / 7 / 0.7 / 0.07A
- Current Resolution – 0.007% of range
- Current Limit of Error – ±1.0% of range
- Set & Read Voltage – >±5.000V
- Cell Voltage Sense Lead – Differential
- Sense Lead Input Resistance – 1.0GΩ
- Modes of Operation – Constant, Scan, Step-Stair; V and I
- Impedance Frequency Range – 1 mHz to 10 kHz
- Impedance Measurement Types – Sweep EIS and Single-Freq HFR Real-Time Measurement, Whole Cell and Aux
- Flow Path – All 316SS
- Liquid Feed Tank – 1x 2L, Auto Fill
- Liquid Feed Concentration – In situ DI Water Conductivity
- Liquid Feed Flow – 50-700 mL/min
- Liquid Feed Temp – Ambient – 95ºC
- Liquid Filtration – In-line De-Ionized Recycling Loop
- Back Pressure – Dual, 0-2 bar g (0 – 30 psig), Manual
- Purge Gas – 2x 0.5 SLPM N2 MFC
- Water/Gas Separation – 2x Auto-Draining Condensers
- Product Mass Flow Measurement – 1 SLPM H2 & O.5 SLPM O2
- Additional Data Acquisition – 7 Temp & 7 Analog (0-5V, 4-20mA)
- Cell Temperature – Ambient – 125ºC
- Cell Connection – 4-Terminal (I+,I-,V+,V-) & Differential Aux (REF)
- Operating Temperature – 5-35º C
- Power Source – 100-120 or 220-240 VAC 50/60 Hz
- Size (excluding tubing connections) – 53 cm x 53 cm x 100 cm (21 x 21 x 39.5 in)
- Weight (empty) – 45 kg (100 lbs)
- Robust – Embedded Firmware Level Decisions
- Fail Safe Design – N2 Purge On Alarm Condition
- Continuous Monitoring – E-Stop, Voltage, Current, Temperate, Gas, Contamination & External Signals
Included with every Scribner is a set of parts and tools for installing the instrument. Specifically, each 600 includes;
-
Tools
- 2 wrenches, 1/2″ & 9/16″, for common fittings
- Document Folder
- USB drive with documentation and software
- Calibration information
-
Cabling
- Country specific power cords bringing wall power to unit
- USB cable connecting Unit to Computer
- Voltage sense cable
- Alarm Accessory Cable
-
Extra Parts
- DI Water Filter Kit
- SS braided PTFE Hoses
- Nuts and ferrules for hoses x8
- Alligator clips x6
- ¼” nuts, bolts, and washers for bus bars x2
- Type T Thermocouple connectors x6
- Analog connector Plugs x6
Adds extra corrosion resistance to the feed stock tanks by coating 316SS in durable Teflon™.
Adds Cleaned for Oxygen Service tubing and fittings on the oxygen side of the product flow path.
Ensure No Organic Contaminates which can act as fuels in oxygen rich environments.