G5.RLD Regenerative DC Electronic Load Series
Delivery and Shipping to EU
Delivery and Shipping to EU
We will add in the quotation, the shipping, insurance, customs clearance costs.
G5.RLD Regenerative DC Electronic Load Series
Regatron
The G5.RLD series are unidirectional, regenerative DC electronic loads: instead of turning the absorbed energy into heat they feed it back to the grid. They operate in CV, CC, CP, CR and Ri-Sim modes and suit industrial and scientific applications in labs, on test benches and in production.
Key features
- Energy fed back to the grid – minimal heat dissipation
- CV, CC, CP, CR and Ri-Sim modes
- Highly dynamic, adjustable filter time constants
- Autoranging factor 3, modular 9…54 kW units, 60 V SELV version
- Systems up to 2000+ kW and 3000 VDC
Device types
| Order code | Voltage (V) | Power (kW) | Current (A) | Height |
|---|---|---|---|---|
| G5.RLD.9.80.338 | 0…80 | 9 | −338…0 | 4U |
| G5.RLD.18.80.676 | 0…80 | 18 | −676…0 | 4U |
| G5.RLD.27.80.1014 | 0…80 | 27 | −1014…0 | 7U |
| G5.RLD.36.80.1352 | 0…80 | 36 | −1352…0 | 7U |
| G5.RLD.45.80.1690 | 0…80 | 45 | −1690…0 | 10U |
| G5.RLD.54.80.2028 | 0…80 | 54 | −2028…0 | 10U |
| G5.RLD.18.160.338 | 0…160 | 18 | −338…0 | 4U |
| G5.RLD.36.160.676 | 0…160 | 36 | −676…0 | 7U |
| G5.RLD.54.160.1014 | 0…160 | 54 | −1014…0 | 10U |
| G5.RLD.27.240.338 | 0…240 | 27 | −338…0 | 7U |
| G5.RLD.54.240.676 | 0…240 | 54 | −676…0 | 10U |
| G5.RLD.36.320.338 | 0…320 | 36 | −338…0 | 7U |
| G5.RLD.9.500.54 | 0…500 | 9 | −54…0 | 4U |
| G5.RLD.18.500.108 | 0…500 | 18 | −108…0 | 4U |
| G5.RLD.27.500.162 | 0…500 | 27 | −162…0 | 7U |
| G5.RLD.36.500.216 | 0…500 | 36 | −216…0 | 7U |
| G5.RLD.45.500.270 | 0…500 | 45 | −270…0 | 10U |
| G5.RLD.54.500.324 | 0…500 | 54 | −324…0 | 10U |
| G5.RLD.18.1000.54 | 0…1000 | 18 | −54…0 | 4U |
| G5.RLD.36.1000.108 | 0…1000 | 36 | −108…0 | 7U |
| G5.RLD.54.1000.162 | 0…1000 | 54 | −162…0 | 10U |
| G5.RLD.27.1500.54 | 0…1500 | 27 | −54…0 | 7U |
| G5.RLD.54.1500.108 | 0…1500 | 54 | −108…0 | 10U |
All 80 V models are also available as 60 V SELV versions (e.g. G5.RLD.9.60.338). Units can be combined in parallel, series or mixed operation to build systems up to 2000+ kW and 3000 VDC. Multi-unit systems are quoted on request.