The 855 SOFC & SOEC Test System is a fully integrated platform for operation, control, and diagnostics of solid oxide fuel cells (SOFCs) and solid oxide electrolysis cells (SOECs).

Designed for research environments, the 855 combines electronic load control, gas handling, furnace integration, and real-time electrochemical diagnostics into a single, cohesive system.

Capable of zero-volt applications for lower measurement range, as well as automated, hands-free switching between SOFC and SOEC mode via FuelCell® software. The 855 is known for it’s high performance and accuracy.—so you can focus on your experiment, not your setup.

  • Integrated turnkey SOFC platform — Bring together load control, gas management, humidification, and furnace interfacing into a single, coordinated system.

  • Multi-range electronic load with zero-volt capability — Accurately test across a wide operating range with a multi-range load (5/25/50 A, 100 W) and zero-volt capability—enabling precise low-voltage measurements critical for SOFC research.

  • Integrated furnace & thermal control — Precision temperature management with built-in safety enables stable, high-temperature operation for long-duration SOFC testing.

  • Advanced gas & humidification control — Maintain accurate and repeatable reactant conditions with flexible flow control and integrated humidification.

  • Real-time electrochemical diagnostics — Access continuous HFR and IR-free voltage measurements for immediate insight into true cell performance.

  • Impedance & electrolysis capability — Expand into deeper diagnostics and SOEC operation with integrated impedance analysis and electrolysis support.

  • FuelCell® software control — Automate complex test protocols and monitor all system parameters through a single, intuitive interface.

  • Built-in safety for high-temperature operation — Operate confidently with integrated safeguards, automatic shutdowns, and system-wide protection.

  • Characterize SOFC performance

  • Study high-temperature electrochemistry

  • Analyze degradation and durability

  • Expand into SOEC and reversible systems

     

    SPECIFICATIONS

    • Load Current Range – 5/25/50 A, 10/50/100 A
    • Maximum Load Power – 100 W
    • Minimum Load Resistance – <2.0 mΩ (125 W, 500 W)
    • Current Resolution – 1 mA
    • Current Accuracy – 0.3% of full-scale current of selected range
    • Max. Whole Cell Voltage – 20V
    • Max. Reference Electrode Voltage – 9.999V
    • Voltage Resoluition – 1 mV
    • Voltage Accuracy – ±3 mV ±0.3% of reading
    • Voltage & Current Data Update Rate – 100 Hz
    • Whole Cell Sense Input Resistance – > 35kΩ
    • Reference Electrode Input Resistance – > 10⁹ Ω


    • 316 Stainless Steel Construction – Humidifiers, flow paths, valves, and mass flow controllers, all with Swagelok® fittings for durability and chemical compatibility.
    • Up to 5 SLM H₂ (Anode) and 10 SLM Air (Cathode) with fully software-controlled MFCs for accurate, repeatable reactant delivery. Additional N2 MFC on anode side for dilute H2 start up procedures.

     

     

    • Alarms – Gas supply pressures (3), Humidifier water levels (1), External (1), System alarm output (1)
    • Fail Safe Design – N₂ purge on alarm condition
    • Continuous Monitoring – E-stop, voltage, current, temperature, gas contamination & external signals

     

    Included with every Scribner is a set of parts and tools for installing the instrument. Specifically, each 855 includes;

    Tools

    • 2 wrenches, 1/2″ & 9/16″, for common fittings

    Document Folder

    • USB drive with documentation and software
    • Calibration information

    Cabling

    • Country specific power cords bringing wall power to unit
    • USB cable connecting Unit to Computer
    • Voltage sense cable
    • Load Cables for connection to the furnace control box and cell

     

    Adds Electrochemical Impedance Spectroscopy (EIS) and High-Frequency Resistance (HFR) measurements for whole cell, or half-cell, diagnostics, monitoring membrane performance over time and under varying operating conditions from 1mHz to 10kHz.

     

    Datasheet.PDF