Ivium Technologies  |  SKU: OctoBoost16000

Multi-channel booster (OctoBoost16000)

Regular price €0,00


Delivery and Shipping to EU

We will add in the quotation, the shipping, insurance, customs clearance costs.

Multi-channel booster (OctoBoost16000)

Ivium Technologies

Product description

Complete solution

The OctoBoost16000 offers a flexible high current solution for both the OctoStats or Ivium single channel instruments. In combination with an OctoStat, the 16A channels on the booster can be combined (as long as the channels are neighbouring) to give a variable max current up to 128A (e.g. 8 x ±16A, 4 x ±32A, 2 x ±64A, 1 x ±64A and 4 x ±16A, 1 x 128A, etc.). This configuration is also possible with multiple single-channel instruments. In combination with a single channel instrument, the OctoBoost16000 functions as a booster for currents up to 128A.

Safety

The maximum current or potential of the instrument can be defined by the operator. Thus valuable samples may be protected, and unsafe situations prevented.

Hardware

  • Current range: 10A and 100A

Software

The OctoStat/OctoBoost16000 is controlled via Ivium’s own software, IviumSoft. This versatile, yet intuitive software, allows instrument control, data management and analysis, etc. The OctoStat can also be controlled from LabVIEWTM, C++, Delphi, etc. A full suite of software is included as standard with each instrument.

  • Control of separate channels individually
  • All channels simultaneously
  • Synchronous start
  • Data from different channels plotted individually or in 1 single graph

 

Specifications

System performance
Current compliance
±16A
Maximum applied voltage
-2 to +9V, or ±5V (user selectable)
Channel combination
Yes
Channel combination configuration
Neighbouring channels combinable, e.g. 4 x ±32A, 2 x ±64A, 1 x ±64A and 4 x ±16A, 1 x ±128A, etc.
Potentiostat
Current ranges
±10A and ±100A
Measured current accuracy
0.025% of FSR
Impedance Analyser
Frequency range
10µHz to 10kHz
Amplitude
0.15mV to 2.0V potentiostatic, or current compliance of the (combination of) channels galvanostatic
Environment
Module height
3U
Specifications subject to change, Ivium Technologies ©2025