G5.BAS Battery Simulator Series
Consegna e spedizione nell'UE
Consegna e spedizione nell'UE
Nel preventivo aggiungeremo i costi di spedizione, assicurazione e sdoganamento.
G5.BAS Battery Simulator Series
Regatron
The G5.BAS series is a bidirectional, regenerative DC power supply built specifically to emulate batteries and energy storage systems on lab benches and test rigs. Running Regatron's BatSim software, it reproduces the electrochemical and electrical behaviour of Li-ion, lead-acid, NiMH and NiCd batteries in charge and discharge mode in real time, so you can develop and validate without real batteries.
Key features
- Battery models for Li-ion, lead-acid, NiMH and NiCd, configurable in BatSim
- Response times in the tens of µs, rise/fall time 150…220 µs
- Voltage accuracy 0.01…0.02% FS, extra high-resolution current range (±10% FS, <0.005% FS)
- CV, CC, CP, CR modes plus internal resistance (Ri) and conductance (Gi) simulation
- Autoranging factor 3, modular 9…54 kW units in 4U/7U/10U
- Integrated safety relay (ISR) up to PL e (EN ISO 13849), 60 V SELV version available
Device types
| Order code | Voltage (V) | Power (kW) | Current (A) | Height |
|---|---|---|---|---|
| G5.BAS.9.80.338.M | 0…80 | 9 | −338…338 | 4U |
| G5.BAS.18.80.676.M | 0…80 | 18 | −676…676 | 4U |
| G5.BAS.27.80.1014.M | 0…80 | 27 | −1014…1014 | 7U |
| G5.BAS.36.80.1352.M | 0…80 | 36 | −1352…1352 | 7U |
| G5.BAS.45.80.1690.M | 0…80 | 45 | −1690…1690 | 10U |
| G5.BAS.54.80.2028.M | 0…80 | 54 | −2028…2028 | 10U |
| G5.BAS.18.160.338.M | 0…160 | 18 | −338…338 | 4U |
| G5.BAS.36.160.676.M | 0…160 | 36 | −676…676 | 7U |
| G5.BAS.54.160.1014.M | 0…160 | 54 | −1014…1014 | 10U |
| G5.BAS.27.240.338.M | 0…240 | 27 | −338…338 | 7U |
| G5.BAS.54.240.676.M | 0…240 | 54 | −676…676 | 10U |
| G5.BAS.36.320.338.M | 0…320 | 36 | −338…338 | 7U |
| G5.BAS.9.500.54.M | 0…500 | 9 | −54…54 | 4U |
| G5.BAS.18.500.108.M | 0…500 | 18 | −108…108 | 4U |
| G5.BAS.27.500.162.M | 0…500 | 27 | −162…162 | 7U |
| G5.BAS.36.500.216.M | 0…500 | 36 | −216…216 | 7U |
| G5.BAS.45.500.270.M | 0…500 | 45 | −270…270 | 10U |
| G5.BAS.54.500.324.M | 0…500 | 54 | −324…324 | 10U |
| G5.BAS.18.1000.54.M | 0…1000 | 18 | −54…54 | 4U |
| G5.BAS.36.1000.108.M | 0…1000 | 36 | −108…108 | 7U |
| G5.BAS.54.1000.162.M | 0…1000 | 54 | −162…162 | 10U |
| G5.BAS.27.1500.54.M | 0…1500 | 27 | −54…54 | 7U |
| G5.BAS.54.1500.108.M | 0…1500 | 54 | −108…108 | 10U |
All 80 V models are also available as 60 V SELV versions (e.g. G5.BAS.9.60.338). Units can be combined in parallel, series or mixed operation to build systems up to 5000+ kW and 3000 VDC. Multi-unit systems are quoted on request.